User Manual

Cell count reconfirm message
The following display is informing you that the pack is at an unsafe voltage level. Double check the pack cell count again. If the cell count is
correct, press [INC] to continue charge.
Lipoly/A123 battery pack charge sequences( see Fig-2)
Lipoly charging sequence is shown below. Each step is specially
designed for the safe lipoy charge algorithm.
Fig-2 Start charge
Fig-3
Balancer data display
Press [SEL] for 2seconds to
display the balancer data
1.
Checking Pack voltage: The charger scans the pack
voltage. It requires 3.2V/cell Lipo and 2.6V/cell A123 as a
minimum voltage to start charge.
Checking balancer: The charger reads the balancer data for
30 seconds. If the balancer connector is not attached,
simply press [INC] to skip the balancer checking mode.
If a balancer is connected to the data port, you can find
the balancer model name, imbalance and pack voltage. It
takes at least 10-30 seconds to get the balancer data.
Initial charge: If the pack voltage is too low, the charge
current will be reduced until the pack voltage reaches a safe
voltage. Wait for the initial charge to finish. If a timeout
error occurs, please charge again or check the pack
conditions. This timeo ut error is caused by an over
discharged pack (see option settings for adjustment of this
timer).
CC Charge (constant current charge):
CV Charge (Constant voltage charge):
Charge is completed.
2.
3.
4.
5.
6.
7.
Press[SEL] for 2 seconds to
Exit.
Charge complete
Charge current adjustment during C/C charge
The charge current setting can be adjusted from 0.25A to 125% of original charge setting while in CC charge.
Press [INC] or [DEC] to change current.
Check balancer data during CC/CV charge:
Press [SEL] key for 2 seconds, the LCD should display as shown in fig-3.
Press INC or DEC to scroll up and down to see each cell and imbalance vo ltage.
Check charge options and input power voltage during charge:
Quickly press [SEL] key, the LCD will display the charge options and input voltage.
**CC (Constant current) charge:
**CV (Constant voltage charge
TP610C
5
THUNDER POWER RC
F- 25.000V 3.0A
00200mAh 0:20:00
C5: 4.100V IntBal
C6: 4.110V 0.010
Li 25.000V 3.0cv
00000mAh 0:00:00
C3: 4.100V IntBal
C4 4.110V 0.010
Li 25.000V 3.0cc
00000mAh 0:00:00
C1: 4.100V IntBal
C2: 4.110V 0.010
Charge 20.000V
Initial charge 05
CH: 4.100V 6sPak
CL: 4.110V 0.010
Balancer Connected
IntBal 1M:0.010
(C)CELL#.1 2 3 4 5 6
B.STATUS o o o o o o
Checking >>>>>
Balancer...
Checking 20.00V
Pack Voltage
XX Cell selected
Charge If Correct
Cell count Error
May Cause Fire