Product Manual
12
5.5 Proper Shutoff Procedures
When the Welding or Cutting Procedure is complete, follow this procedure.
1. Close the oxygen control valve on the torch handle.
2. Close the fuel control valve on the torch handle.
3. Close both cylinder valves.
4. Open the oxygen control valve on the torch handle to release remaining pressure.
5. Turn the pressure adjusting screw on the oxygen regulator clockwise until it spins freely.
6. Close the oxygen control valve on the torch handle.
7. Open the fuel control valve on the torch handle to release remaining pressure.
8. Turn the pressure adjusting screw on the fuel regulator clockwise until it spins freely.
9. Close the fuel control valve on the torch handle.
10. Ensure all regulator gauges read zero.
11. Recommended: Close cylinder valves for storage.
12. You may leave all equipment connected. Protect from dirt, dust, grease, oil and damage.