User's Manual

6
Performance Parameter
Value
Measured voltage (BATT+)
7 ~ 32V (hw rev 3.0)
7 ~ 65V (hw rev 3.1)
Measured voltage accuracy
max 0.5%, typ. 0.25% (hw rev 3.0)
max 0.2%, typ. 0.1% (hw rev 3.1)
Measured current
-500A to 500A
Current monitoring accuracy (using integrated shunt)
0.5% - without calibration
0.25% - with calibration
Integrated current shunt resistance
0.15 mOhm / ±0.25%
Power
max. 30000W
Power meter
more than 1000 MWh
Charge meter
more than 1000 MAh
Temperature
1°C / 1°F resolution
Data logging sample rate
1 sec up to 18 days
2 sec up to 36 days
5 sec up to 90 days
10 sec up to 180 days
20 sec up to 1 year
30 sec up to 1.5 years
1 min up to 3 years
Current draw (current consumed by the device) (using
the latest firmware version)
at 12V
at 24V
at 32V
at 48V
at 65V
hw rev 3.0 hw rev 3.1
3.5 mA 1.5mA
3.7 mA 1.6mA
4.0 mA 1.7mA
------ 1.8mA
------ 1.9mA