How to Guide

service@thorgroup.us +1 877-288-8099
Step 2
1. Make sure all the front burners are taken out from grill cavity;
2. Use 6mm tool (included in NG conversion kit) to take out original (LP) orifices from the burner valve
inside the grill cavity, then put in NG orifices. Detailed orifice information are shown below:
NG orifice (included in NG Conversion Kit)
Part #
Part Name
Size
Quantity
10.05.008007-000-A0
Front Broil Burner
Orifice - NG
1.52mm
1
10.05.008005-000-A0
Main Tube Burner
Orifice - NG
1.44mm
3
LP Orifice (came with product, need to be replaced by NG orifice)
Part #
Part Name
Size
Quantity
10.05.008006-000-A0
Front Broil Burner
Orifice - LP
Φ1.07mm
1
10.05.008014-000-A0
Main Tube Burner
Orifice - LP
Φ1.02mm
3
3. Take out all the burner knobs (total 5 knobs, one for front infrared broiler burner, three for tube burners
and one for back infrared broiler burner) and get access to adjustment of burner valve;
4. Use flat screwdriver (LP/NG screwdriver in the kit) to adjust the burner valve for NG use. Turn the stem
clockwise all the way to the end for NG position; for adjusting back to LP use, counter-clockwise all the
way to the end LP position.