Step 5
Safety and Performance Check after NG Conversion:
1. All the distance between electrode needle and burner orifice should be around 3 – 5 mm (0.11 – 0.19
inch)
2. Check all gas connection with Bubble test (detailed procedures please follow Step 4 – 4)
3. Check the regulator gas pressure (4- inch water column for NG)
4. Check the burner BTU for each burner (BTU is not changing after NG Conversion)
5. Check the flame condition (See below picture)
- Visually check the burner flames. They should be blue or slightly yellow.
- Check and clean all burners/ venturi tubes for insects and insect nests. A clogged tube can lead to
fire hazard under the outdoor cooking grill.