Installation Guide
Instructions for Converting Range Top to Operate on Liquefied Petroleum Gas
3.Griddle Orifice install (only for 4806 Range Top)
a. Remove back panel and backsplash by removing 6 screws inside the ventholes, 4 screws 2 on
each side of the back panel and bottom row screws on the back panel which should be about 4 to
5
b. Once having access to back you would remove the black screws with screwdriver
c. Remove brass fitting by using a wrench to untighten the nut to put in 1.16/1.22 orifice
d. You can now put everything back together.
4. Convert Burner Valves for LP/Propane Gas (for HRT3618U/HRT4806 Range Top)
a. Remove control knobs, bezel and control panel
b Using a flat screwdriver, replace gas valve bypass jets with bypass jets for LP, Tighten the bypass
completely until bottom out and then back off a whole 360°.
c Save the main bypass jets, in the plastic bag labeled main jets and simmer bypass jets in the bag for
simmer jets.
When you are using your top burners, if the flame needs to be adjusted accordingly to fit your need,
please adjust the bypass orifices on the burner valve.
Put back the knob on and adjust the flame by rotating the bypass via a small flat screw driver. Check the
flame’s condition to get the best performance.
For single valve, it has one bypass orifice; For Dual valve, it has two bypass orifices: left bottom one for
simmer adjustment and right front one for main burner adjustment.