Range Hood Installation Guide and User Manual Applicable model: HRH3001U HRH3002U HRH3003U HRH3004U HRH3005U HRH3006U HRH3601U HRH3602U HRH3603U HRH3604U HRH3605U HRH3606U HRH4801U HRH4802U HRH4805U HRH4806U
Safety Notice Approved for residential type units for residential use only read these instructions and be safe. Please read these instructions completely before starting. The installation of the appliance must respect all codes. Important: Save these instruction so that you can provide the electrical inspector in your area. Safety Warning: Turn off the circuit in the electrical panel and lock front panel to connect the cord of this unit. Power requirement: 110V-120V/60HZ.
do not go out immediately, LEAVE AND CALL THE FIRE DEPARTMENT. 2. NEVER PICK IP A FLAMMING PAN. You could be hurt. 3. DO NOT USE WATER, including Dish towels or wet towels-a violent steam explosion of dew may be occurred. 4. Use an extinguisher only if: . You are sure to have a Class ABC extinguisher that you know how to use. . The fire is small and confined to the area where it was formed. .Firefighters was called. .You can fight against the fire with an exit behind you.
Electrical requirements and installation requirements Power Requirements IMPORTANT Observe all governing codes and ordinances. The customer is responsible for: Contacting an electrician installer. Check that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI / NFPA 70 (latest edition *) or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 (the latest edition **) of the CSA, and all codes and ordinances in your area.
Examples and positioning possibilities ducts Follow the letter of the guidelines presented in this manual. The manufacturer declines any liability with respect to any loss, damage or fire caused by non-observance of the instructions contained in this manual. Ventilation methods: The hood is equipped with a vertical transition to remove fumes outside. Recommended diameter conduit model and wall chimney hood and hood island: vertical round pipe 7'' tolerance + or – 1.
Do not cut a joist or stud unless it is absolutely necessary to do so. If you need to cut a joist or stud, you must build a support framework, hardware supplied can secure the hood to most walls and ceilings. However, you should ask a qualified technician to check the strength of materials depending on the type of wall or ceiling. Before cutting, make sure there is enough clearance in the ceiling or wall for the outlet pass. You can determine for yourself how high you install the hood above the stove.
Clearance Training Caution: When install the hood, the height should not be too high or too low. Before the installation, please inspect the maximum height of your ceiling and bonnet.Too high, will affect the efficiency of the hood; too low, stove temperature will damage some parts of the hood.
Installation If possible, unplug the stove and move it in order to have better access to the rear wall. Otherwise, place a thick blanket on the counter and the cooking surface to protect it from damage and dirt. Select a flat surface for assembling the device. Then put the debris of the cover and hardware on to the protective cap. Determine and mark the center line on the wall where you installed the canopy hood. Determine a comfortable height for the user and mark it on the wall behind the stove top.
Necessary Tools 8
03 Series range hood Walled mounted fixed plated 9
Overview size : 10
Installation dimension figure of 04 series range hood as below: 11
04 series range hood Walled mounted fixed plated 12
Overview size : 13
01 series, 02 series range hood 14
05 series 30 inch and 36 inch range hood 15
05 series 48 inch range hood 16
06 series 30 inch and 36 inch range hood 17
06 series 48 inch range hood 18
Installation dimension figure for 01 series, 02 series 05 series and 06 series range hood 1.Fix 6pcs screws( see figure 4) to the installation dead plate 2.Fix the installation dead plate to the wall by screws( see figure 5) 3.Use double-faced aluminum foil sealed-joint( see figure 6) 4.Power line color (black to black, white to white, green to green) (see figure 7) 5.Oil box of the hood (see figure 8) 6.
Figure4 Figure 5 20
Description orders for 01 series, 03 series and 04 series range hood Automatic activation control function of the sensor: There are 5 pieces sensor buttons,1pc remote control signal lamp(remote controller included), 2 pieces stainless steel grease boxes,2 pieces stainless steel baffle filters and 2 pieces led bulbs( 12V/1.5W). A0 button: Remote control signal lamp A1 button: Power( on/off) A2 button: LED bulb A3 button: Display screen A4 button: Time Delay.
Bulb control Press A2 button once, turn on the lights, and again to turn off. Press A2 button or A4 button, then will not able to turn on LED light. Warning: In case of any scald, do not touch LED light, unless hood is closed or cooled. A0 button: same as above. Remote sensor: A0 is the remote control.Remote sensor to receive infrared (IR) remote control signal.
MAINTENANCE WARNING Before servicing or cleaning unit, switch power off at service panel and lock in access to prevent it being switched on accidentally. If the power panel can not be locked, put a prominent warning device, such as a brightly colored label. Grease filters The grease filters should be cleaned once a month or as needed. To remove grease filter, pull the metal latch down. This will disengage the filter hood. Tilt the filter down, then remove.
WARRANTY This product has been manufactured by Thor Group.1335 Fortune Bay Ct,Hoffman Estates IL 60192. Thor Group disclaims all express warranties except for the following: This warranty applies to products purchased and located in the United States. Products purchased or located outside this area are excluded.
The warranty applies to appliances purchased and used for personal, family or household purposes only. It does not cover appliances used for commercial applications.Should the appliance be sold by the original purchaser during the warranty period, the warranty shall extend to the new owner until the expiration date of the original purchaser’s warranty period. Warranty and Product Registration Thor Group is not responsible for incidental or consequential damages.