Operation Manual
4
The minimum distance between the container support area on the cooking appliance and
the lowest part of the range hood must not be less than 50cm in the case of electric cookers
and 65cm in the case of gas or mixed cooker.
If the installation instructions for the gas hob specify a greater distance, this must be taken
into account
Warning ! Failure to follow the instructions in this Instruction Book may cause electrical
hazards. If in doubt, consult an authorized service centre or an authorized technician.
Electrical connection
The electrical connection of the hood to the electrical system must be performed by
qualified and specialized technical staff.
The voltage must correspond to the rating indicated on the nameplate located inside the
hood. If there is a socket, connect the hood to a wall socket compliant with the standards
in force and located in an area accessible after installation as well. If there is no socket
(direct connection to the electrical circuit), or if it is not in an area accessible after
installation too, apply a standard circuit breaker to ensure the complete disconnection of
the hood from the mains under conditions of overvoltage category III, in accordance with
installation instructions. Attention! Before reconnecting the hood circuit to the power
supply and checking the efficient operation, always check that the power cable is
correctly assembled.
The hood is equipped with a special power cable; in the event of cable damage, you must
order a new one to the Technical Support Service
Downloaded from www.vandenborre.be