Operation Manual

373
System Commands
E-DOC-CTC-20040210-0030 v1.0
system config
Show/set SpeedTouch™ system configuration parameters.
Note For a good operation of UPnP™ and the discovery mechanism, it is highly recommended not to change the
system config settings.
SYNTAX:
where:
EXAMPLE:
system config [upnp = <{disabled|enabled}>]
[mdap = <{disabled|enabled}>]
[drst = <{disabled|enabled}>]
[led = <{green|red|orange|flash|off}>]
[digestauth = <{disabled|enabled}>]
[strictusername = <{disabled|enabled}>]
[dcache = <{disabled|enabled}>]
upnp Enable or disable UPnP™ discovery. The default is enabled.OPTIONAL
mdap Enable or disable proprietary discovery protocol.
The default is enabled.
OPTIONAL
drst Enable or disable DrSpeedTouch access. The default is enabled.OPTIONAL
led Set the SpeedTouch™ system LED color. Choose between:
green: solid green
red: solid red
orange: solid orange
flash: toggle between green and orange
off: LED is off.
The default is green.
OPTIONAL
digestauth Enable or disable HTTP digest authentication. The default is disabled.OPTIONAL
strictusername Enable or disable strict username check. The default is disabled.OPTIONAL
dcache Enable or disable data cache. The default is enabled.
Note For internal use only. Do NOT alter in any way.
OPTIONAL
=>system config
upnp discovery : enabled
mdap discovery : enabled
drst support : enabled
digest authentication : disabled
strict username : disabled
dcache : enabled
=>