2.1.31. "FLO 2 MODULATOR" window
This window is called up y pressing the "NEXT SCREEN" control keys in the "MODULATOR FLO 1"
window.
It displays the MediaFLO modulator card parameters used in the
b
exciter.
MESSAGES FUNCTIONS SELECTIONS
AVAILABLE/COMMENTS
Gives the name windows
Displays actual values of the modulati
parameters.
on
Infra ID: This value is inserted into
the infrastructure ID field of the Local
system parameters message. The
network sets this field to the identifier
assigned to the local area
infrastructure.
LT Offset: This value is inserted into
the local time offset field of the local
system parameters message.
Daylight: ON / OFF
This indicator is inserted into the
daylight field of the local system
parameters message.
ON: Local transmitter time is daylight
saving time.
Displays actual values of the channelizer
parameters.
Nat Len: Exciter initialization register
indicates National Length.
Loc Len: Exciter initialization register
indicates Local Length.
PP Len: Exciter initialization register
indicates Positioning Pilot Length.
Fr1 Len: Exciter initialization register
indicates FrameLength.
WID Val: Exciter initialization register
indicates WID scrambler sequence
number.
LID Val: Exciter initialization register
indicates LID scrambler sequence
number