Operation Manual Part 2

Digital Liquid Cooled UHF
TV Equipment
Description / Test points / Location of units
9946 V1
45321648.01 104 A E
preliminary
68 / 131
Numéro / Number Doc. Rev. Lan
g
u.
16/06/2006
Pa
g
e
Information contained is this document is confidential, is THOMSON property and cannot be disclosed in whatever form without prior written authorization of THOMSON.
3.6.12. Environmental Conditions
Guaranteed specifications (alt1500m) : 0 à 55°C.
Guaranteed operation : -10 à 60°C.
Storage temperature : -30 à 60°C.
Relative humidity : 95 % without condensation.
3.6.13. Mechanical Characteristics
size including handle and connector (W x H x D) : 230x60x70 mm.
weight : 0.8 kg max
3.6.14. Electrical Characteristics
The electrical characteristics below are given for above environmental conditions.
Input max. level without destruction: 20 dBm max.
Output power (1 dB compression on VSWR 1.2 and 470 F 862 MHz):
0.8 W min.
Instantaneous bandwidth: 470 à 862 MHz.
Gain in bandwidth:
21 dB
± 1 dB.
Gain linear distortions in 470 à 862 MHz for 20 dBm:
± 0.75 dB max.
Input matching in bandwidth: 10 dB min.
Output matching in bandwidth: 10 dB min.
Shoulders for Ps = 100 mW rms: - 40 dBc min.
Mains power supply: 240 Volts AC.