User's Manual Part 2
Driver Section - 100 -
®
Affinity LBD-200C-N1 Transmitter
Product Manual
11.2.5 Upconverter Module Power-On Sequence
When power is applied to the Upconverter Module, a display test is performed. The front panel
of the LCD is illuminated for approximately one second then extinguished. This sequence
provides verification that the front panel LCD and MCU logic is functioning. Upon completion of
the display test, the LCD will display the Upconverter Module status as determined by the
firmware tests.
Navigating the front panel assembly:
THALES BROADCAST & MULTIMEDIA is the default display
To view the status of the system and each plug-in module, press
the SEL button as many times as necessary.
Press SEL once=Local/Remote Mode
Press SEL once = Status menu
Status=Xmit, Fail or NoPwr
Press ENT once to enter the TX Control state
Press ENT or SEL to choose Xmit or Stdby or ESC to Quit to
Status Menu
Press Save to store chosen state of operation; TX enters state
then exits to Status menu.
From Status menu; Press SEL once=Power Supply
Status=Pass or Fail
From Status menu; Press SEL twice =Local Oscillator
Status=Pass or Fail
From Status menu; Press SEL three times = Upconverter
Status=Pass or Fail
Press ENT to examine lower level parameters, ESC to return to Upconverter menu
Press SEL four times=Back to Power supply. From this point, pressing SEL will scroll through
the list again.
When at the desired Upconverter status, press ENT followed by SEL as many times as
necessary to view additional information about the plug-in module parameters.
The first ENT=[In Signal]
Yes or No
Press SEL once= [System Fwd Power]
Power=100
Press SEL twice=[System Ref Power]
Power = 0
Press SEL three times=[Upconv Fwd Power]
Power=100
Press SEL four times=[Back to In Signal]