User's Manual Part 2

Exciter Configuration Description - 64 -
®
Affinity LBD-200C-N1 Transmitter
Product Manual
:R Reset Synthesizer
To reset the module, type “:”; capital “R” then press enter.
This performs a software reset, be aware that invoking reset will force a temporary mute of the
output.
:E<freq> Set Frequency
To set frequency, type “:”; capital E then 10 digit frequency ex: 0500000000; then press enter
Use this command to change the frequency of operation. Always enter a full 10-digit frequency
after the command character.
:F Toggle LFC
To set LFC: type, “:”; capital “F”; then hit enter. (Toggles current value engages or disengages
the circuit)
This allows the user control over the loop filter bandwidth, and can be used to override the
default setting. The user should use caution, and be monitoring the phase noise characteristics
of the output during this adjustment.
:0 Show A2D 0
To check reference detector ATD value, type “:”;0 then press enter.
This displays the external reference level after the analog to digital conversion.
:1 Show A2D 1
To check RF level ATD value, type “:”;1 then press enter
This displays the output level after the analog to digital conversion.
:2 Show A2D 2
Unused at this time
Command functions (REAR port only):