Affinity System Reference & Theory of Operation 32
Affinity Control User’s Guide
Software v2.50
EMSET Variable Affinity Control Equivalent & Access
ALC_MODE_SELECT Not directly accessible. Automatically set as
appropriate for software operation.
ALC_AUTO_REF_MIN Not directly accessible. Automatically set during the
Full Upconverter Calibration procedure as part of
the upconverter initialization.
ALC_AUTO_REF Accessed during the Full Upconverter Calibration
procedure. Also, the Main Control screen Raise &
Lower buttons adjust this value up or down in steps
of 1.
ALC_MANUAL_REF Not directly accessible. Adjusted during the Full
Upconverter Calibration procedure.
FAST REFLECTED SHUTDOWN THRESHOLD Accessible in the Metering/LCD Display Calibration
screen. Also adjusted during the Full Upconverter
Calibration procedure.
POWER LIMITER Not directly accessible. Adjusted during the Full
Upconverter Calibration procedure.
FILTER_COEFF_1 Not directly accessible. Automatically set during the
Full Upconverter Calibration procedure as part of
the upconverter initialization.
FILTER_COEFF_2 Not directly accessible. Automatically set during the
Full Upconverter Calibration procedure as part of
the upconverter initialization.
SYSTEM FWD PWR REFERENCE Accessible in the Metering/LCD Display Calibration
screen. Also adjusted during the Full Upconverter
Calibration procedure.
SYSTEM REFLECTED PWR REF Accessible in the Metering/LCD Display Calibration
screen. Also adjusted during the Full Upconverter
Calibration procedure.
UPCONVERTER INTERNAL FRD PWR REF Accessible in the Metering/LCD Display Calibration
screen. Also adjusted during the Full Upconverter
Calibration procedure.
SYSTEM REFLECTED POWER PERCENT LIMIT Not directly accessible. Adjusted during the Full
Upconverter Calibration procedure.
UPCONV HEALTH PLAN MASK Not directly accessible. Automatically set during the
Full Upconverter Calibration procedure as part of
the upconverter initialization.
UNUSED WORD 1 Not directly accessible. Automatically set during the
Full Upconverter Calibration procedure as part of
the upconverter initialization.
Table 2 EMSET Variables to Affinity Control Software Cross Reference