User's Guide
Program Operation 28
Affinity Control User’s Guide
Software v2.50
This step will perform the
adjustment on the Fast Reflected
Power Percent Limit value in order
to set the trip point for full system
power shutdown. Normally, this is
accomplished automatically.
However, in some cases the value
may need to be decreased by one
or two percent.
Figure 41 Full Calibration-Fast Refl Power Percent Limit
Calibration
This is an informational only step
instructing the operator on
configuring the reflected power
sample to the input of the
upconverter. Normally, a reflected
coupler with the same attenuation
factor as the forward power sample
is used. If one is not available, the
attenuation of the chosen reflected
sample coupler can be adjusted
with fixed attenuators. This step is
also the final step of the calibration
procedure, and clicking on the Next
button will exit the procedure.
Figure 42 Full Calibration-Reflected Power Sample Setup