Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Jacketed Metal Clad Cable Termination Fittings
STAR TECK XP
®
Jacketed Metal Clad
Cable Fittings for Hazardous Locations
SEALING COMPOUND
CABLE CABLE REQUIRED
HUB RANGE OVER RANGE OVER DIMENSIONS (IN.) SC65** SC4-KIT**
SIZE JACKET (IN.) ARMOR (IN.) A PUTTY LIQUID
CAT. NO. NPT MIN. MAX. MIN. MAX. MIN. B* C (G) (CC)
STX050-462
1
⁄2 0.525 0.650 0.415 0.570 0.395 2.50 1.63 7 4
STX050-464
1
⁄2 0.600 0.760 0.490 0.680 0.485 2.50 1.63 7 4
STX075-465
3
⁄4 0.725 0.885 0.615 0.805 0.612 2.62 1.82 14 7
STX075-466
3
⁄4 0.825 0.985 0.715 0.905 0.720 2.62 1.82 14 7
STX100-467 1 0.880 1.065 0.770 0.985 0.755 2.83 2.30 30 16
STX100-468 1 1.025 1.205 0.915 1.125 0.900 2.83 2.30 30 16
STX125-469 1
1
⁄4 1.187 1.375 1.077 1.295 1.062 3.05 2.51 45 22
STX150-470 1
1
⁄2 1.357 1.625 1.240 1.545 1.182 3.76 3.26 80 43
STX150-550 1
1
⁄2 1.500 1.625 1.390 1.545 1.370 3.76 3.26 80 43
STX150-471 1
1
⁄2 1.600 1.875 1.490 1.795 1.470 3.76 3.26 80 43
STX200-472 2 1.700 1.965 1.590 1.885 1.557 4.05 3.62 125 66
STX200-473 2 1.900 2.187 1.790 2.107 1.757 4.05 3.62 125 66
STX200-474 2 2.100 2.375 1.990 2.280 1.995 4.15 4.02 150 80
STX250-475 2
1
⁄2 2.300 2.565 2.200 2.485 2.185 4.31 4.58 341 164
STX250-476 2
1
⁄2 2.500 2.750 2.380 2.656 2.365 4.31 4.58 341 164
STX300-478 3 2.580 2.840 2.477 2.750 2.460 5.64 5.10 497 239
STX300-479 3 2.790 3.060 2.677 2.970 2.660 5.80 5.33 609 293
STX350-480 3
1
⁄2 3.000 3.270 2.880 3.190 2.864 6.32 5.79 965 464
STX350-481 3
1
⁄2 3.210 3.480 3.080 3.390 3.062 6.32 5.79 965 464
STX400-482 4 3.420 3.690 3.307 3.590 3.290 6.63 6.19 1323 636
STX400-483 4 3.610 3.870 3.477 3.770 3.460 6.63 6.19 1323 636
STX400-484 4 3.810 4.030 3.650 3.930 3.630 7.09 6.90 1645 791
STX400-485 4 3.965 4.185 3.794 4.065 3.775 7.09 6.90 1645 791
* Approximate dimension before installation.
** 1 unit of SC65 putty type sealing compound contains 60 g. 1 unit of SC4-Kit liquid type sealing compound
contains 66 cc and includes a dispensing syringe and fiber damming material.
CAUTION: STAR TECK XP
®
fittings must be installed with Thomas & Betts catalog numbers
SC4-Kit or SC65 sealing compound (purchase separately). See installing instructions.
Sealing Compounds
CAT. NO. DESCRIPTION VOLUME
SC65 Putty Type Sealing Compound 60 grams
SC4-KIT Liquid Type Sealing Compound for use in high wire density applications 2.8 fl. oz. (66 cc)
(5 or more wires)
Hub
(aluminum)
Grounding Ring
(stainless steel)
Gland Nut
(aluminum)
Bushing
(elastomer)
Retaining Ring
(stainless steel)
B
C
A
UL Connectors when Used with Putty Type
Listed or Liquid Type Compound For:
1
⁄2 thru 3" Class I Div. 1 Groups A, B,
C, D
Class II Div. 2 Groups F, G
Class III
Enclosure Type 4
Connectors when Used with Putty Type
or Liquid Type Compound
3
1
⁄2" & 4" Class I Div. 1 Groups B, C, D
Class II Div. 2 Groups F, G
Class III Enclosure Type 4
CSA Certified For:
Class I Division Groups A, B,
1 and 2 C, D
Class II Division Groups E,
1 and 2 F, G
Class III, SL (Integral Seal)
Enclosure Type 4
A-95
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com