Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Jacketed Metal Clad Cable Termination Fittings
STAR TECK EXTREME
®
—
STE/STEX Series Cable Fitting
Application
• Provides means for passing jacketed
metal clad cables through a bulkhead
or enclosure in industrial and
hazardous areas. (These fittings are
suitable for hazardous areas when
used with T&B sealing compound.)
• Forms a mechanical grip and water
and/or oil-resistant termination
• Provides grounding continuity
of cable armor
Features
• Powergrip grounding ring
• Removable armor-stop for greater
cable ranges
• Built-in sealing device
• Elastomeric collar ring/ bushing
for greater cable ranges
• Built-in jacket stripping gauge
on gland nut
• Gland nut can be tightened
with hammer and screwdriver
Range
• STAR TECK EXTREME
®
fittings are
designed to accommodate a broad
range of cables. Each hub range
overlaps the adjacent hub range,
thereby minimizing the possibility
of mismatched cables and fittings
in the field. They are available in
hub sizes from
1
⁄2" to 4" and will
handle outer jacket diameters
form 0.525" to 4.340".
Materials
• Aluminum is standard material
• Add suffix “S” for steel with
zinc plating
• Add suffix “PVC” for corrosion
resistant PVC coa
ting
• Add suffix “SS” for
stainless steel ma
terial
Cable Type
• JMC, MC-HL, Teck
Environment Classification
• STE* Series
–Ordinary Location
–Class I, Division 2†
• –NEMA 4, 4X (stainless steel), 6P
• –STE050 — STE200
NEMA 6P
• –STE250 — 400
NEMA 4
• –STE050 — 400
NEMA 4X (stainless steel)
• STEX** Series
–Class I,
Division 1, Groups A, B, C, D
–Class II, Division 1, Groups E, F, G
–Class III
–NEMA 4, 4X (stainless steel), 6P
• UL Listed for Direct Burial when
made from stainless steel material
• Suitable for use in wet locations and
concrete tight (steel) a
pplications per
UL 514B
• UL File No. E82038/E38947
• CSA File No. LR638/LR23086
* These fittings are suitable for Class I hazardous locations
when used in combination with a certified Class I
hazardous location sealing fitting.
** May be used in hazardous areas with approved MC-HL
or Teck cable (or equal) when installed in accordance
with NEC/CEC requirements.
Not applicable to all STEX series.
The STAR TECK
®
STE cable fitting series is designed for optimum integrity in ordinary applications.
The STEX series is specially designed for classified hazardous areas. Both are designed to stand
up to the harshest and most corrosive environment.