Cut Sheet

Rigid and Intermediate Metal Conduit Fittings
ABCDE
TRADE MAX. PANEL THROAT
CAT. NO.
SIZE DIA. THICKNESS DIA.
H050GR-TB
1
2 1
7
16 1
9
16
7
8
3
16
19
32
H075GR-TB
3
4 1
7
16 1
19
32
29
32
3
16
25
32
H100GR-TB 12 1
13
16 1
1
16
1
4 1
H125GR-TB 1
1
4 2
3
8 1
7
8 1
1
16
1
4 1
5
16
H150GR-TB 1
1
2 2
3
4 1
7
8 1
1
16
1
4 1
17
32
H200GR-TB 23
1
4 1
15
16 1
5
32
1
4 1
31
32
H250GR-TB 2
1
2 3
3
4 2
9
16 1
9
16
1
4 2
13
32
H300GR-TB 34
3
8 2
7
16 1
19
32
1
4 2
31
32
H350GR-TB 3
1
2 52
23
32 1
5
8
1
4 3
13
32
H400GR-TB 45
1
2 2
23
32 1
5
8
1
4 3
7
8
H500GR-TB 56
7
8 3
1
32 1
15
16
1
4 4
15
16
H600GR-TB 67
11
16 3
5
32 2
5
16 6
TRADE GROUND MAX. CONDUCTOR
CAT. NO.
SIZE DIA. HEIGHT SCREW SIZE
L050GR-TB
1
2 1
1
2
13
32 #10-32 x
1
4" #10
L075GR-TB
3
4 1
11
16
13
32 #10-32 x
1
4" #10
L100GR-TB 12
13
32 #10-32 x
1
4" #10
L125GR-TB 1
1
4 2
3
8
15
32
1
4-20 x
1
4" #10
L150GR-TB 1
1
2 2
3
4
15
32
1
4-20 x
5
16"#8
L200GR-TB 23
1
4
15
32
1
4-20 x
5
16"#8
L250GR-TB 2
1
2 3
3
4
11
16
1
4-20 x
5
16"#6
L300GR-TB 34
3
8
23
32
1
4-20 x
5
16"#6
L350GR-TB 3
1
2 5
23
32
1
4-20 x
5
16"#6
L400GR-TB 45
1
2
23
32
1
4-20 x
5
16"#4
L500GR-TB 56
5
8
23
32
3
8-16 x
3
8"#2
L600GR-TB 67
11
16
23
32
3
8-16 x
3
8"#1
Material – Locknut: zinc or copper-free aluminum UL File No. E-3060
For Aluminum Locknuts add suffix A. (i.e., L050GRA) CSA File No. 4484
For Chrome-Plated Locknuts add suffix CP. (i.e., L050CP). For 316 Stainless Steel Locknuts
add suffix SST (
1
2
" through 2" only.) For Locknut with Lay In Lug add suffix GRL
DIA.
T&B Hub Centerline Spacing Chart
CONDUIT
TRADE SIZE
1
2"
3
4"1"1
1
4"1
1
2"2" 2
1
2"3" 3
1
2"4" 5" 6"
1
2"1
9
16
3
4"1
43
64 1
25
32
1" 1
27
32 1
61
64 2
1
8
1
1
4"2
1
32 2
9
64 2
5
16 2
1
2
1
1
2"2
7
32 2
21
64 2
1
2 2
11
16 2
7
8
2" 2
15
32 2
37
64 2
3
4 2
15
16 3
1
8 3
3
8
2
1
2"2
23
32 2K 3 3
3
16 3
3
8 3
5
8 3
7
8
3" 3
1
32 3
9
64 3
5
16 3
1
2 3
11
16 3
15
16 4
3
16 4
1
2
3
1
2"3
11
32 3
21
64 3
5
8 3
13
16 44
1
4 4
1
2 4
13
16 5
1
8
4" 3
19
32 3
45
64 3
7
8 4
1
16 4
1
4 4
1
2 4
3
4 5
1
16 5
3
8 5
5
8
5" 4s 4
9
16 4
3
4 4
15
16 5
3
16 5
7
16 5
3
4 6
1
16 6
5
16 7
6" 4
11
16 4J 4
31
32 5
5
32 5
11
32 5
19
32 5
27
32 6
5
32 6
15
32 6
23
32 7
13
32 7
13
16
Nearest Obstruction
27
32
61
64 1
1
8 1
5
16 1
1
2 1
3
4 22
5
16 2
5
8 2
7
8 2
9
16 3
31
32
to Center of Hub
T&B Grounding Hub
T&B Grounding and
Bonding Locknut
Material – Hub and Locknut: zinc or copper-free aluminum
Insulating Throat: thermoplastic temp. rating –
105°C
Flammability Rating – 94V-0
Sealing Ring: Nitrile (BUNA “N”)
For Aluminum Hubs add suffix A (i.e., H050A). For Chrome-Plated
Hubs add suffix CP (i.e., H050CP). For 316 Stainless Steel Hubs
add suffix GRSST (i.e., H050GRSST).
(1
2
" through 2" only.) Meets
NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures.
UL Listed and CSA Certified. CSA Certified for hazardous
locations Class II Groups E.F.G. Class III.
UL File No. E-23018 CSA File No. 4484
Chrome-Plated Hubs (suffix-“CP”) are rated NEMA 4X.
Grounding Locknut for Hubs
Throat Dia. E
D
B
A
C
A-18
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com