Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Non-Metallic Sheathed Cable Fittings
Steel or malleable iron.
Two-Screw Connectors
Rounded cable grip and smooth bushing protect the cable sheath and wire
insulation. Because saddle is threaded, screws do not travel or extend beyond
the connector body as it is clamped to the cable. An extra lip on the saddle
closes the unused part of the connector opening.
• Threaded saddle means screws don’t travel or extend beyond
connector body as it’s clamped to cable
• Extra lip on saddle closes unused part of connector opening
• Steel or malleable iron construction
• Look for the unique T&B blue color ensuring the highest quality fitting
NON-INSULATED INSULATED UL LISTED & CSA CERTIFIED UL LISTED & CSA INSULATED
CAT. CAT.
K.O. FOR THE FOLLOWING SINGLE (1) CERTIFIED FOR THE FOLLOWING IN. CABLE OPENING (IN.)
NO. NO.
SIZE AND PAIRS OF (2) NM & NMC CABLE SERVICE ENTRANCE CABLES A B C MAX. MIN.
3302-TB* 3302M-TB
1
⁄2" (1) 2#14, 2#12, 2#10, 3#14, 2#12 thru 2#4, 3#12, 3#10 1 1
13
⁄32 1 .590 .250
3#12, 3#10, (2) 2#14, 2#12
3303-TB 3303M
3
⁄4" (1) 2#8, 2#6, 3#8 2#8 thru 2#1/0, 3#8, 3#6, 1
1
⁄4 1
5
⁄8 1
1
⁄8 .750 .530
(2) 2#12, 2#10, 2#8, 3#14 2#6 + #8 GND
(1) 3#8, 3#6, 3#4 2#1, 2#1/0, 3#6 thru 3#2,
3304 3304M 1" (2) 2#8, 3#10 2#4 + #6 GND, 2#3 + #5 1
1
⁄2 1
7
⁄8 1
1
⁄4 .990 .690
GND, 2#2 + #4 GND
(1) 3#8, 3#6, 3#4 3#2 thru 3#2/0, 2#1 + #3
3305 3305M 1
1
⁄4" (2) 2#8, 2#6, 2#4, 3#8 GND, 2#1/0 + #2 GND, 1
29
⁄32 2
1
⁄4 1
1
⁄4 1.320 .850
2#2/0 + #1 GND
3306 3306M 1
1
⁄2" (1) 3#4, 3#6 3#3/0, 3#4/0, 2#3/0 + #1/0 2
3
⁄16 2
5
⁄8 1
9
⁄16 1.530 .930
GND, 2#4/0 + #2/0 GND
3307 3307M 2" Max. 1.98", Min. 1.15" — 2
3
⁄4 3
1
⁄4 1
7
⁄8 ——
3308†— 2
1
⁄2" Max. 2.38", Min. 1.5" — 3
1
⁄4 3
15
⁄16 2
3
⁄16 —
—
3309† — 3" Max. 2.88", Min. 1.75" — 3
13
⁄16 4
9
⁄16 2
9
⁄16 1.980 1.150
3310†— 3
1
⁄2" Max. 3.38", Min. 2.25" — 4
7
⁄16 5
1
⁄4 2
27
⁄32 ——
3311† — 4" Max. 3.88", Min. 2.5" — 4
7
⁄8 5
15
⁄16 3
3
⁄32 ——
*
UL Listed for use with rubber and thermoplastic flexible cords (both single and multiple cords and 2 oval cables).
†
Not UL Listed or CSA certified.
UL Listed for multiple cords and cables.
CSA File No. 2884
UL File No. E-23013 –
1
⁄
2
" – 1
1
⁄
2
"; U.L. File No. E-15170 – 2"
A-166
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
B
A
C