Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Metal Clad Cable, Armored Cable and Flexible Metal
Conduit Fittings
TITE-BITE
®
Connectors
3110 Series
Application
• To connect and effectively bond metal
clad cables, armored cable or flexible
metal conduit to a box or an enclosure
Features
• Provided with an angled saddle
designed to:
(1) Firmly secure conduit in place without
damaging cable armor (Mechanical
holding power of angled wedge assembly
increases with increased strain.)
(2) Provide high quality bond between conduit
or cable and is unaffected by vibrations
• Insulated throat protects conductors
during and after installation and
reduces wire pull effort
• Heat-curled insulator in throat:
(1) Better protects conductors due
to funnel entry
(2) Reduces pulling force due
to rotating design
(3) Won’t pull out
• Locknuts designed to provide effective
bond between connector and box or
enclosure, will not vibrate loose
• Designed with fewer installing
screws — reduces installation time
and labor cost
• Armor stop with viewing window
• Rugged all steel or malleable
iron construction
• Suitable as a grounding means per
NEC Article 348 for flexible metal
conduit, NEC Article 320 for armored
cable and NEC Article 330 for metal
clad cable
• Suitable for hazardous location use
per Class 1 Division 2 NEC 501.10 (b)(2)
Typical Installation
Standard Material/Finish
Body . . . . . . . . . . . . . . . . . Steel or malleable iron/
Electro Zinc Plated &
Chromate Coated
Saddle . . . . . . . . . . . . . . . Steel/Electro Zinc Plated
& Chromate Coated
Screws . . . . . . . . . . . . . Steel/Electro Zinc Plated &
Chromate Coated
Insulator . . . . . . . . . . . . . Thermoplastic/As Molded
Listings/Compliances
UL 514B
CSA C22.2 No. 18
NEMA FB1
UL (UL File No. 23018)
CSA (LR-2884, LR-4484)
RANGE HUB SIZE CONDUIT SIZE CABLE OPENING
3110 Series Straight Connectors
1
⁄2" to 4" NPS
3
⁄8" to 4" .470" to 4.560"
3130 Series 90° Connectors
1
⁄2" to 4" NPS
3
⁄8" to 4" .470" to 4.560"
(All hubs provided with straight pipe threads NPS)
Locknut
Saddle
Body
Box or Enclosure Wall
Insulated Throat
A-157
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com
Super-Fast
Installation!
Super-Fast
Installation!
Up to 2X faster
than standard
connectors!
Very High
Cable Pull-Out
Resistance!
Very High
Cable Pull-Out
Resistance!
Now UL Listed
for New Interlocked
Armor Ground Type
Metal Clad Cable
(MCI-A)!
Now UL Listed
for New Interlocked
Armor Ground Type
Metal Clad Cable
(MCI-A)!