Cut Sheet
Table Of Contents
- T&B Fitting
- Product Overview
- Rigid & Intermediate Metal Conduit Fittings
- Form 7, Form 8, Series 35, Conduit Outlet Bodies & Covers
- Mogul Conduit Outlet Bodies
- FS/FD Cast Device Boxes and Covers
- Conduit Outlet Boxes
- Conduit Outlet Elbows, Reducers, Plugs, and Adapters
- Three-Piece Couplings
- Sealing Fittings
- Kopr-Shield Compound
- Jacketed Metal Clad Cable Termination Fittings
- Tray Cable Fittings
- EMT Fittings
- Liquidtight Flexible Metal Conduit Fittings
- Shureflex™ Nylon Conduit System
- XTRA FLEX System
- Flexible Cord and Cable Fittings
- Flexible Cord and Cable Fittings - Non-Metallic
- Service Entrance Cable Fittings
- Metal Clad Cable, Armored Cable and FlexibleMetal Conduit Fittings
- Non-Metallic Sheathed Cable Fittings
- Conduit Dimensional Data
Liquidtight Flexible Metal Conduit Fittings
Straight Liquidtight Fittings — HT
CAT.
CONDUIT DIMENSIONS
NO.
SIZE A B C
5331-HT
3
⁄8" 1
5
⁄32" 1
1
⁄2"
9
⁄16"
5332-HT
1
⁄2" 1
3
⁄8" 1
9
⁄16"
9
⁄16"
5333-HT
3
⁄4" 1
21
⁄32" 1
5
⁄8"
9
⁄16"
5334-HT 1" 1
7
⁄8" 2
1
⁄16"
3
⁄4"
5335-HT 1
1
⁄4" 2
9
⁄32" 2
1
⁄2"
13
⁄16"
5336-HT 1
1
⁄2" 2
22
⁄32" 2
11
⁄16"
13
⁄16"
5337-HT 2" 3
1
⁄4" 3
1
⁄16"
7
⁄8"
5338-HT 2
1
⁄2" 3
3
⁄4" 4
1
⁄8" 1"
5339-HT 3" 4
1
⁄2" 4
1
⁄4" 1"
5340-HT 4" 5
1
⁄2" 4
1
⁄2" 1
1
⁄8"
A
B
45° Liquidtight Fittings — HT
CAT.
CONDUIT DIMENSIONS
NO.
SIZE A B C
5341-HT
3
⁄8"1
5
⁄32"1
9
⁄16"
9
⁄16"
5342-HT
1
⁄2"1
3
⁄8"
7
⁄8"
9
⁄16"
5343-HT
3
⁄4"1
21
⁄32"2
1
⁄8"
9
⁄16"
5344-HT 1" 1
7
⁄8"2
1
⁄4"
3
⁄4"
5345-HT 1
1
⁄4"2
9
⁄32"2
3
⁄4"
13
⁄16"
5346-HT 1
1
⁄2"2
22
⁄32"2
3
⁄8"
13
⁄16"
5347-HT 2" 3
1
⁄4"3
7
⁄8"
7
⁄8"
90° Liquidtight Fittings — HT
CAT.
CONDUIT DIMENSIONS
NO.
SIZE A B C
5351-HT
3
⁄8" 1
5
⁄32" 1
3
⁄8"
9
⁄16"
5352-HT
1
⁄2" 1
3
⁄8" 1
9
⁄16"
9
⁄16"
5353-HT
3
⁄4" 1
21
⁄32" 1
3
⁄4"
9
⁄16"
5354-HT 1" 1
7
⁄8" 2
3
⁄16"
3
⁄4"
5355-HT 1
1
⁄4" 2
9
⁄32" 2
3
⁄4"
13
⁄16"
5356-HT 1
1
⁄2" 2
22
⁄32" 2
5
⁄16"
13
⁄16"
5357-HT 2" 3
1
⁄4" 3
7
⁄16"
7
⁄8"
C
A
B
A
B
C
C
52
®
Series High-Temperature Flexible Metal Liquidtight Fittings
Where liquidtight flexible metal fittings are required in high-temperature environments up to 150° C:
• Fitting’s body, gland, locknut and
ground cone shall be constructed
from steel or malleable iron, electro-
zinc plated and chromate coated for
corrosion protection
• Fitting’s sealing ring and throat
insulator will be molded from high-
temperature nylon, suitable for
temperatures up to 150° C and a
minimum UL flammability rating
of UL94-V2
• The fitting shall be constructed to
accept high temperature flexible
metal liquidtight conduit rated to
150° C
• The fitting shall have a plastic throat
insulator to protect conductors
• The fitting shall have a steel ground
cone to:
— provide high quality ground contact
— single helical thread for easy installation
into conduit
— rolled over edge to protect conductors
• The fitting shall have a plastic
sealing ring to:
— grip and seal at leading and trailing edge
(double bevel up to 2") of conduit jacket
— provide a watertight/oiltight seal
• The fittings shall be capable to
terminate the conduit in either
a threaded or threadless opening
• For applications where termination
into a threaded opening is required,
the fitting shall have external
taperedNPT threads
• Fittings shall conform to UL 514B
• Accepted Manufacturers: Thomas &
Betts — 5331-HT straight series,
5341-HT 45° series, 5351-HT 90°
series; 5262 sealing ring series
ATX Flexible Liquidtight Conduit
CONDUIT LENGTH INSIDE BEND
CAT NO.
SIZE (FT.) RADIUS (IN.)
ATX038-TB
3
⁄8" 100 1.5
ATX050-TB
1
⁄2" 100 2.0
ATX075-TB
3
⁄4" 100 2.5
ATX100-TB 1" 100 3.0
ATX125-TB 1
1
⁄4" 50 3.5
ATX150-TB 1
1
⁄2" 50 4.5
ATX200-TB 2" 50 5.5
ATX250-TB 2
1
⁄2" 25 8.0
ATX300-TB 3" 25 10.0
ATX400-TB 4" 25 12.0
T&B HT-Series
Liquidtight Fittings
are available straight,
45° and 90°.
A-110
United States
Tel: 901.252.8000
800.816.7809
Fax: 901.252.1354
Technical Services
Tel: 888.862.3289
www.tnb.com