User Guide

Programmer3.0 Specific TR65 Commands
Any Normal TR65 command may also be sent (radio control etc)
Send command with no parameters to GET the current value
HC<2 ASCIIHEX> -- CORRECT Minimum loop time control - units are
milliseconds
HH<2 ASCIIHEX> -- HOLDOFF inhibit Trigger time control - units are
milliseconds
HI<ACTION RETRY COUNT (1 ASCIIHEX)><OPEN RETRY COUNT
(1 nibble)> -- ITERATE Controls looping retry paramters
HL<OFF> -- LOCK Inhibit LOCK command in ENCODE loop
HL<LOCK PAYLOAD (5 ASCIIHEX)> -- LOCK Set the LOCK command
payload
HP<2 ASCIIHEX> -- PAUSE Delay after Trigger time control - units are
milliseconds
HQ<1 ASCIIHEX> -- QUIET Delay after OPEN - units are milliseconds
HT<OFF or R or F> -- TRIGGER Control TRIGGER INPUT - off or edge
type RISING FALLING
HW<1 ASCIIHEX> -- WAIT Override GEN2 ASYNC WAIT - units are
milliseconds
Copyright 2014 Thinkify LLC. All Rights Reserved.
Thinkify, LLC, 18450 Technology Drive, Suite E1, Morgan Hill, Ca. 95037, www.thinkifyit.com 408-782-7111