Setup Guide
Table Of Contents
- Notices
- About Thinkify, LLC
- A Quick RFID Introduction
- Thinkify Reader Protocol Overview
- Command Reference
- Summary
- "A" – RX Amplifier Control
- "BOOTLOADER" – Enter Bootloader
- "C" – Low-Level Chip Control Registers
- "F" – RX Filter Control
- "G" – GPIO Settings
- “I” – Inventory Control
- "K" – Kill, Lock, Access Descriptors
- “M" – MASK / SELECT control
- “NM" – Macro Control
- "P" – PROTOCOL control (Gen2 Air protocol)
- "R" – RF Control
- "RP" and "RM" – Multiplexing (Antenna Control)
- "T" – Initiate INVENTORY
- "X" – eXtra Data Read and Write Descriptor Control
"X" – eXtra Data Read and Write Descriptor Control
READY>t51
STARTINVENTORY
TAG=3000E2003411B802011029356733
XRD0=E2003411B8020110
STOPINVENTORY 0x0039 EPCCOUNT=1
Read Extra Data in T<n> Command
// Do 10 (0xA) iterations of T6
READY>t6A
STARTINVENTORY
TAG=3000E2003411B802011029356733 924250 05 E B I 1FBF
XRD0=E2003411B8020110
TAG=3000E2003411B802011029356733 926750 00 E C Q 1FF0
XRD0=E2003411B8020110
TAG=3000E2003411B802011029356733 926750 02 E C Q 2007
XRD0=E2003411B8020110
TAG=3000E2003411B802011029356733 926750 06 E C I 201E
XRD0=E2003411B8020110
TAG=3000E2003411B802011029356733 926750 02 E C I 2038
XRD0=E2003411B8020110
TAG=3000E2003411B802011029356733 926750 06 E C Q 204F
XRD0=E2003411B8020110
TAG=3000E2003411B802011029356733 926750 05 E C Q 2068
XRD0=E2003411B8020110
TAG=3000E2003411B802011029356733 926750 03 E C I 2081
XRD0=E2003411B8020110
STOPINVENTORY 0x00DB EPCCOUNT=8
Set a Write Descriptor, Then Get It
READY>xw0114021111222233334444
WRDESCRIPTOR=0
ACTIVE=1
BANK=1
LEN=4
PNTR=02
WRITEDATA=1111222233334444
READY>xw0
WRDESCRIPTOR=0
ACTIVE=1
BANK=1
LEN=4
PNTR=02
WRITEDATA=1111222233334444
Set and Use a Write Descriptor
// 1st read a tag
READY>t5
STARTINVENTORY
TAG=3000E2003411B802011029356733
STOPINVENTORY 0x0034 EPCCOUNT=1
// Set up to rewrite part of the EPC
51