Setup Guide

Table Of Contents
"X" – eXtra Data Read and Write Descriptor Control
"X" – eXtra Data Read and Write Descriptor Control
X[<R|W>[<PARAMS>]]
Anytime an EPC code is acquired from a tag, an opportunity exists to either read additional
data from the tag, or write data to it. These options are controlled by XDATA descriptors
managed by the X commands.
The TR265 reader maintains four (4) XDATA read descriptors and four (4) XDATA write
descriptors that may be individually configured to perform read/write operations.
By default all XDATA descriptors are disabled. When a tag's EPC is decoded, each of the XDATA
descriptors are checked for an ACTIVE status, which causes a read/write at the specified
location to be performed. Inside an inventory mode which supports XDATA (currently T, T5,
and T6) the operations will be performed right after the read of the EPC data, and the data
appears on the line of output immediately following the EPC data in the tag stream.
Flags
<PARAMS> may contain some or all of the following:
<#> Descriptor number
<ACTIVE> Descriptor enabled
<MEMBANK> Tag memory bank for the operation
<LEN> Length (in words) of data to be read/written
<EBV> EBV pointer into memory for the start of the operation
<DATA> The bytes of data to be written.
Sub-Commands
Sub Command Description Legal Values
for SET
XR
Report all XDATA read descriptors.
-
XRR
Reset all XDATA read descriptors. -
XR<#>
Report a given XDATA read descriptor. 0..3
XR<#><ACTIVE>
Set the <ACTIVE> flag for XDATA read descriptor <#>. 0..1
XR<#><ACTIVE><...>
Configures XDATA read descriptor <#> to perform a read at
the specified location and length.
XR<#><ACTIVE><MEMBANK><LEN><EBV>
<ACTIVE> 0=inactive, 1=active
<MEMBANK> 0..3
See Description
49