Owner manual
Configuring Readers
74 Level 2 API
/reader/gen2/target
Type: Gen2.Target
Default value: Gen2.Target.A
Writable: yes
Products: all
Controls the target algorithm used for read operations. See
Tag Contention Settings for
details.
/reader/gen2/Tari
Type:Gen2.Tari
Default value: From reader
Writable: yes
Products: M6e, M6
Controls the Tari value used for communications with Gen2 tags. See the M6e Hardware
Guide for full configuration options.
See
Reader-to-Tag Settings for details.
/reader/gen2/writeReplyTimeout
Type: Integer
Default value: 20000
Writable: yes
Products: M5e, M6e
Controls the time, in microseconds, each word write operation (a
Gen2.WriteTag and
Gen2.WriteData consists of multiple word write operations) will wait for a tag response
before moving to next word write. Great caution must be taken when changing this
parameter. Not all tags take the same amount of time to complete each word write. If the
time is shortend to less than the time a tag takes to perform each word write, the write
operation will fail. The Gen2 specification dictates that all tags must complete and
respond to a word write in 20ms or less. Some tags take less than 3ms, some close to
20ms
– Max. timeout = 21000us