Specification

102813‐25
**NOTETOSPECIFIER**Thefollowingaretypicalmountingheights.Indicatemounting
heightsonDrawingsordesignateaspartofSpecification;donotindicatemountingheightsin
bothSpecificationsandDrawings
a. Men'sToilets:45inches(1143mm).
b. Women'sToilets:43inches(1092mm).
c. Teenagers'Toilets:41inches(1041mm).
d. YoungChildren'sToilets:35inches(889mm).
e. ToiletsforPersonswithPhysicalDisabilities:37inches(940mm).
f. MountdryersatheightsindicatedonDrawings.
PART3EXECUTION
3.1 EXAMINATION
A. Donotbegininstallationuntilsubstrateshavebeenproperlyprepared.
B. Ifsubstratepreparationistheresponsibilityofanotherinstaller,notifyArchitectof
unsatisfactorypreparationbeforeproceeding.
3.2 PREPARATION
A. Cleansurfacesthoroughlypriortoinstallation.
B. Preparesurfacesusingthemethodsrecommendedbythemanufacturerfor
achievingthebestresultforthesubstrateundertheprojectconditions.
C. Coordinaterequirementsforblockingtoensureadequatemeansforsupportand
installationofhanddryers.
D. Coordinaterequirementsforpowersupply,conduit,disconnectswitchesand
wiring.
3.3 INSTALLATION