INSTALLATION
Fixing
This appliance can be front or side fixed, holes are provided for either installation method.
Front Fixed Appliance Side Fixed Appliance
1 front fix hole each side of Grill opening 1 side fix hole each side of Grill opening
1 front fix hole each side of Oven opening 1 side fix hole each side of Oven opening
2 fixing holes in each Hotplate side trim 2 fixing holes in each Hotplate side trim
Make sure the appliance is fully home in the cabinet/aperture prior to screw fixing.
When installing DO NOT lift appliance using the door handles
Connection - Gas
A ¼” BSP taper gas inlet connection is provided on the rear of the appliance. Refer to the
diagrams at front of booklet for the location of the gas inlet. It is recommended that the
appliance is connected by copper tubing. A rubber or hose connection must not be used.
After connection the appliance must be tested for soundness.
This appliance is suitable for use on
PROPANE GAS ONLY 2.75Kpa.
It is important that the regulator should be set to the correct pressure for the type of gas being
used. Excessive pressure must not be permitted.
If the flame on either the top burners or the grill should show a tendency to lift, it is possible
that the line pressure is too great. Should there be excessive yellow tips (resulting in sooting)
then it is possible that the line pressure is too low. In either case the burners should not be
used until the line pressure has been checked out.
The burners on this appliance have fixed aeration and no adjustment is necessary.
Connection - Electrical
The appliance is supplied with a power cord and plug which must be connected to a double
pole switched mains supply, with 3mm minimum contact separation at all poles.
Any excess power cord MUST be routed away from the appliance and not come into contact
with the appliance or hang loose into a lower compartment.
When satisfied with the appliance, please instruct the user on the correct method of operation.
If the appliance fails to operate correctly after all checks have been made, refer to the
authorised service provider in your area.
This appliance must be earthed
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or a similarly qualified person in
order to avoid a hazard
After installation the appliance MUST be tested for soundness
Test ALL burners on high and low flame for flame stability.
The gas supply input pressure MUST not rise or fall significantly
from nominal when ALL appliances connected to the supply are
operated simultaneously.