FAULT DIAGNOSIS
FAULT
CAUSE
SOLUTION
Burner will not adjust
(continuous on low or high
flame).
Gas pressure
Blocked jet
Control tap
Check gas pressure correct
Clear blockage from jet.
Check jet size correct
Inspect/test control tap
Burner sooting. Gas pressure
Check pressure, low pressure is the cause of
sooting.
Burner – no Spark Ignition
Power supply
Poor connection
Spark generator
Check power supply
Check all connections
Test spark generator
Earth leakage due to damaged wire
Burner will not remain lit
Thermocouple
failure.
Blocked jet
Test & replace thermocouple if required
Check thermocouple in flame path
Clear jet blockage
In the event that this appliance cannot be adjusted to perform correctly and for any service
assistance, please contact your authorised local Service Agent giving details of the model and
serial number from the data badge on the underside of the appliance, plus the date of purchase.