Owner Manual
Installation /Owner’s Manual 15
Your dealer or an authorized Thetford Service Center must do this
procedure.
Make sure the combustion seal [29] is not broken, is completely
around the refrigerator mounting anges, and is between the
mounting anges and the wall of the enclosure (See Art02454).
If the combustion seal is not complete, exhaust fumes can be
present in the living area of the vehicle. The breathing of exhaust
fumes can cause dizziness, nausea, and in extreme cases, death.
1. Push the refrigerator completely into the enclosure.
2. Put the screws though the upper and lower mounting anges at the front of the
refrigerator.
The rear of the refrigerator has sharp edges and corners. To
prevent cuts or abrasions when working on the refrigerator, be
careful and wear cut resistant gloves.
4. Open the lower intake vent and put the screws through the mounting ange at the rear
of the refrigerator and into the oor.
To avoid possible LP gas leaks, always use two wrenches to loosen and tighten the LP gas supply line at
the refrigerator’s manual shut off valve.
5. Attach the LP gas supply line to the manual shut off valve of the refrigerator.
6. Open the valve at the LP gas tank(s).
Do not allow the leak checking solution to touch the electrical components. Many liquids are electrically
conductive and can cause a shock hazard,electrical shorts, and in some cases re.
7. Examine the LP gas supply line for leaks.
8. Connect the DC wiring to the refrigerator:
- Install the DC fuse or connect the DC wiring to the battery or the converter.
- Connect the DC supply to the refrigerator’s DC wire harness.
9. Connect the AC power cord to the receptacle.
Reinstall the Refrigerator
Replacement Parts
You may purchase replacement parts through your local RV dealer or an authorized Thetford Service Center.
CAUTION
!
NOTICE
WARNING
!
WARNING
!
WARNING
!
Art02454
40
28
29