Owner Manual
Owner’s Manual 7
Ignition – LP gas operation
- Open the valve on the LP gas storage tank.
- Put the refrigerator into LP gas mode.
- Set the refrigerator at the maximum cooling setting.
You will hear a clicking sound indicating that the controls are sending a spark to the burner. If the ame does not
ignite within 30 seconds, the gas safety valve will close and the gas indicator ( ) and temperature LEDs will begin
to ash. Switch the refrigerator off and on and select the gas source again.
- If the ame does not ignite after several attempts, contact your dealer or authorized Thetford Service Center.
- When the burner lights, set the refrigerator to the desired cooling level.
Start up – AC operation
- Make sure that 230VAC power is available to the refrigerator.
- Put the refrigerator into AC mode ( ).
- Set the desired cooling level.
Start up – DC operation
- Make sure that 12VDC power is available to the refrigerator.
- Put the refrigerator into DC mode ( ).
- Set the desired cooling level.
Shut down:
Press and hold the on/off button for two (2) seconds. All LEDs will turn off.
NOTICE