User’s Manual Thank you for purchasing our product. Carefully read this instruction manual before using this unit. Copyright 2004 T&D Corporation. All rights reserved. 2004.
Notices about this User’s Manual In order to properly use this product, please carefully read this manual before using.T&D Corporation accepts no responsibility for any malfunction of and/or trouble with this product or with your computer that is caused by the improper handling of this product and will deem such trouble or malfunction as falling outside the conditions for free repair outlined in the attached warranty. - All rights of this User’s Manual belong to T&D Corporation.
Safety Precautions and Instructions DANGERS To ensure safety be sure to obey all of the following warnings. Do not take apart, repair or modify the main unit. Doing so may cause fire or electrocution. The following items should be strictly obeyed for the safe usage of this unit, and for protecting yourself and other people from bodily harm and/or damage to property. To ensure the proper use of our product, please read the following carefully and fully understand the contents.
CAUTIONS Do not use batteries other than specified. Doing so may cause fire or damage. Battery terminals may provide insufficient contact due to age or vibration. This may lead to data loss. Condensation may occur if the unit is moved from one environment to another where the difference in temperature is great. Use the unit in an environment where the ambient temperature is from -10 to 60℃ and the humidity is 90% RH (no condensation) or less.
Cautions about using the Sensors Cautions about using the temperature sensor TR-0106 The possible temperature measurement range for this sensor is -40 to 110℃ . Please use it within this range. Cautions about using the Sensors [Handling the temperature/humidity sensor] - The temperature/humidity sensor should probably be changed after a period of about one year. After removing the sensor from its package, please change the temperature/humidity sensor after one year’s usage.
Contents Safety Precautions and Instructions -----------------------------------------iii About Thermo Recorder TR-71U/72U --------------------------------------- 1 Package Contents ---------------------------------------------------------------- 3 Part Names and Functions ----------------------------------------------------- 5 Installing the Battery ------------------------------------------------------------- 7 Turning on the Power ------------------------------------------------------------ 8 Installing
Battery Life Warning Display When the battery power becomes low, a battery life warning signal will appear in the unit’s LCD display. If the battery power becomes even lower the unit will automatically go into sleep mode in order to protect the data. 15 Recording Intervals Package Contents The following items are included in the package: 【TR-71U】 Select from 15 Recording Intervals (from 1 second to 1 hour) to meet your needs.
Part Names and Functions 【TR-72U】 Part Names [FRONT] Thermo Recorder TR-72U × 1 unit T&D Recorder for Windows Software CD-ROM × 1 DISPLAY button AA Alkaline Battery (LR6) × 1 USB Communication Cable US-15C × 1 Temperature Sensor TR-3100 × 1 Sensor Jack (Channel 1) Software User’s Manual × 1 REC/STOP button DISPLAY :Pressing this button will change the LCD display mode. INTERVAL :Pressing this button will display the currently set recording interval.
Installing the Battery LCD Display 1.Remove the battery cover form the back of the unit. ② ③ ④ ⑤ ⑥ 2.Insert 1 AA alkaline battery, making sure that the + and – are in the correct direction. - Always use a new battery. ⑦ ① ⑧ ① Channel Mark The channel number of the measurement being displayed will appear. ② Recording Mark The recording condition will appear. ON :Recording in progress. BLINKING:Waiting for programmed start.
Turning on the Power Installing the USB Device Driver 1. By holding in the POWER switch at the left side, the unit will turn on. You will need to install this driver in order to use the device with a USB cable and Windows. It is necessary for communication via USB between your computer and any TR-71U/72U device. After installing, your computer will be able to detect and recognize TR-71U/72U devices that have been connected with a USB cable.
4.By connecting a data logger to the USB cable already connected to your computer, the [Add Hardware Wizard] will automatically open. 5.By checking [Install the Software automatically (Recommended)] and clicking [Next], the software will automatically be installed. Checking After Connecting 1.Open the [Control Panel] and double click on [System] ; the system properties will be displayed. 2.Click the [Hardware] Tab, and click the [Device Manager] button in the Device Manager Area.
6.Check [Search for a suitable driver for my device (recommended)] and click the [Next] button. For Windows 2000: 1.Turn on your computer and open Windows. 2.After Windows has been completely started up, connect the supplied USB cable to a USB port on your computer. Check [Next] button 3.Insert the attached CD-ROM in the CR-ROM drive. ※ If the Installation Window opens, close it. 4.
Checking After Connecting 8.By clicking the [Next] button, installation will begin. 1.Open the [Control Panel] and double click on [System]; the system properties will be displayed. 2.Click the [Hardware] Tab, and click the [Device Manager] button in the Device Manager Area. 「Hardware」Tab [Next] button Caution: If the Driver is not automatically detected, please search by specifying the place as (CD-ROM [Device Driver]) and install manually from there. Device Manager [Device Manager] button 9.
6.After completing installation, click the [Finish] button. For Windows Me: 1.Turn on your computer and open Windows. 2.After Windows has been completely started up, connect the supplied USB cable to a USB port on your computer. [Finish] button Caution: If the Driver is not automatically detected, please search by specifying the place as (CD-ROM [Device Driver]) and install manually from there. 3.Insert the attached CD-ROM in the CR-ROM drive. ※ If the Installation Window opens, close it. 4.
Checking After Connecting For Windows 98: 1.Open the [Control Panel] and double click on [System]; the system properties will be displayed. 1.Turn on your computer and open Windows. 2.Click the [Device Manager] Tab, and the [Device Manager] Window will appear. 2.After Windows has been completely started up, connect the supplied USB cable to a USB port on your computer. 「Device Manager」Tab 3.Insert the attached CD-ROM in the CR-ROM drive. 「USB Recorder1」 ※ If the Installation Window opens, close it.
6.Check [Search for the best driver your device (Recommended)] and click the [Next] button. 8.Click [Next] to start the installation. Check [Next] button 7.Check [Specify a location] and click the [Browse] button. Select the [Device Driver] in the CD-ROM drive and click [Next]. [Next] button 9.After completing installation, click the [Finish] button.
Checking After Connecting 1.Open the [Control Panel] and double click on [System]; the system properties will be displayed. Connecting the Sensor Connecting the Sensor. [TR-71U] 2.Click the [Device Manager] Tab, and the [Device Manager] Window will appear. 「Device Manager」Tab If a temperature sensor is connected to only the ch. 2 jack, the internal sensor will be used to measure for ch. 1. - To avoid poor connections, be sure to push the sensor connector securely into the jack.
[Handling the temperature/humidity sensor] - The temperature/humidity sensor should be changed after a period of about one year. After removing the sensor from its package, please change the temperature/humidity sensor after one year’s usage. During use, the temperature/humidity sensor will accumulate impurities (dirt) on the surface of the sensor causing the sensor's accuracy and sensitivity to decrease.
Setting Recording Interval from Main Unit Switch If Installation Fails You can make or change recording interval settings from the "INTERVAL" switch on the front of the TR-71U/72U main unit. If, during USB device driver installation, some trouble occurs that results in a failure to install properly, the following display will appear in the Device Manager. 1.Press in the [INTERVAL] button on the front of the device until the recording interval appears in the display. 2.
Specifications Device Type Optional Accessories Temperatue Sensors(For TR-71U) TR-71U TR-72U No. of Measurement Channels 2 Channels (Select from ch1. internal / ch.2 external) 2 Channels (1 Temperature / 1 Humidity) Measurement Items Temperature Temperature Humidity Internal Temperature Sensor -10 to 60℃ -10 to 60℃ - Attached Sensor -40 to 110℃ 0 to 50℃ 10 to 95% RH Optional Temp.
TR-0206 Stainless Protection Sensor Sensor Extension Cable(Temp Sensor Only) Cable Length : 0.6m Thermal-Constant Time : In the air : Approx. 75 Sec. TR-1C30 unit : millimeters Cable length : 3.0m TR-0306 Stainless Protection Sensor Cable Length : 0.6m Thermal-Constant Time: In agitated water : Approx 18 Sec. Materials: ① Vinyl Coated Electrical Wire ※ Only stainless section is water resistant TR-0406 Stainless Protection Sensor Cable Length : 0.
Serial Communication Cable (for TR-71U/72U) TR-07C Serial Communication Cable Cable Length:about 1.0 m Connector Type:Specialized Connector D-sub9pin For communication with computer TR-4C10 Serial Communication Cable Cable Length:about 1.
Provisions for Free Repair 5652-169, Sasaga, Matsumoto City, Nagano, 399-0033 Japan Tel: +81-263-27-2131 Fax: +81-263-26-4281 E-mail: overseas@tandd.co.jp Office Hours :Monday to Friday 9:00-12:00/13:00-17:00 (GMT +9:00 Tokyo Time) [Home Page] We have opened an English Homepage called "T&D Online" for your convenience. Here you can find information about our company, news, products, upcoming events, software and user’s guides downloads, as well as, other support.