Instruction Manual

Instrument Operation
Press the button to activate the thermometer.
Temperatures will be displayed and the display will auto-rotate
depending on orientation. The thermometer will turn off
automatically after 10 minutes. This can be disabled. Press
and hold the button for 3 seconds to turn instrument off.
To activate the backlight, press the button once while the
instrument is turned on. Press again to turn off.
Insert the stainless steel probe to the desired depth. The
measured temperature will be shown on the LCD display
within 2-3 seconds.
Care and Cleaning
Clean the probe immediately after each measurement to avoid
cross contamination. Do not expose the entire thermometer to
temperatures over 190°F (88°C). Do not leave inside ovens.
Technical Support
For warranty, service, and technical assistance, please
contact ThermoWorks’ Technical Support at (801) 756-7705
or email at techsupport@thermoworks.com.
For additional cooking tips and doneness temperatures, and
to see the full line of ThermoWorks tools, visit our website at
www.thermoworks.com.
Specifications
Battery Installation
Replace the battery when low battery symbol ‘Bat’ flashes.
Replace with a 3-volt, type CR2032, button-cell battery or
equivalent.
Use a screwdriver of suitable size to open the battery cover
on the back.
Install the battery observing the correct polarity, (+) positive
side up, sliding the battery under the metal clip.
Close the battery cover. Do not overtighten.
Auto-Off
To disable:
Press the button 6 times. Display will flash OFF twice
To enable:
Press the button 6 times. Display will flash ON twice.
Auto-off setting is saved even if instrument is turned off.
ThermoPop
®
2
Operating Instructions
ThermoPop 2
To Select °F or°C
Press and hold the button for 3 seconds upon start-up.
Range
Accuracy
Resolution
Response
IP Rating
Operating Range
Probe
Auto-Off
Auto Backlight
Battery
Display
Product Size
Certificate
–58 to 572°F (–50 to 300°C)
±1.0°F (±0.5°C) between 14 to 208°F (–10 to 98°C)
±4.0°F (±2.0°C) between 392 to 572°F (200 to 300°C);
otherwise ±3.0°F (±1.6°C)
0.1° from –19.9 to 99.9°, otherwise 1°
2-3 seconds
IP67
32 to 122°F (0 to 50°C)
4.5 L x 0.1 inch dia. reduces to 0.06 inches dia.
(114 L x 2.5 mm dia. reduces to 1.5 mm dia.)
After 10 minutes, can be disabled
10 seconds
CR2032 (3V) lithium coin cell x 1, 5,000 hours
1.25 dia. inches (32 dia. mm);
7 H x 1.8 W x 0.8 D inches
(178 H x 45.4 W x 17.5 D mm)
Includes NIST-traceable Calibration Certificate
360° auto-rotating display
Includes calibration certificate
Super-Fast
®
2-3 seconds
Splash-proof design
Bigger backlit digits
Wide range –58 to 572°F
Guaranteed accuracy ±1°F to 208°F
Switchable °C/°F

Summary of content (2 pages)