Operating Manual

Chapter 4 Set up Additional Measurements Accu-Wave
4-6 TN Technologies
Measurement Display Setup
In the default configuration, the 4-line display can show 3 measurements readouts (or up to
6 measurements by alternately displaying 3 readouts at a time). The fourth line displays
the instruction “For setup, press .”
Like the primary measurement, the signal strength (sig str) measurement is displayed by
default. If the tank volume setup has been completed, the tank volume is also displayed by
default. For example if you have set up volume, the measurement display would be similar
to the display shown in Figure 4.1 below.
10.5 ft level
78.5 cu ft
114 sig str
For setup press
Figure 4.1 Measurement Display (level, volume, signal strength)
The primary measurement is shown on the first line, the volume is shown on the second
line, and the signal strength is shown on the third line. Any additional measurements, up to
six total, would be displayed in alternation with the current measurement readouts. For
example, if measurement 2 is now set up as “%full,” the measurement display would
alternate approximately every 3 seconds between the displays shown in Figure 4.2a and in
Figure 4.2b.
10.5 ft level
64.5 % full
78.5 cu ft
For setup press
10.5 ft level
64.5 % full
114 sig str
For setup press
a. Display 1 (level, % full, volume) b. Display 2 (level, % full, sig str)
Figure 4.2 Measurement Display (level, volume, signal strength, % full)
To make room for displaying other measurements or to eliminate the need for the display
to alternate between measurement screens, you can disable the display of the “For setup,
press ” instruction on the fourth line of the measurement display. The display of this line
is disabled using a menu item under the “Special functions” menu, see page 8-19.
Note: Pressing the key from the measurement display will access the setup
menus even if the display of the “For setup” instruction is disabled.
If you do not want signal strength to appear on the measurement display, it can also be
disabled using a menu item under the “Special functions” menu, see page 8-19.
You can also disable the display of the primary measurement (measurement 1) as follows.
Use the “Special functions” menu (see page 8-19) to enable the service only items. This
adds a “Modify measurement 1” menu under the “Additional measurements” menu which
includes the “Do / Do not display” option for primary measurement readout.