Operating Manual

Chapter 9 Security, Service & Diagnostics Accu-Wave
9-12 TN Technologies
Factory Service & Related Items” Menu (cont.)
[Service only item]
Display Comments
signal diagnostics
Menu subgroup header. See “Signal diagnostics”
menu table below.
Factory test
!!! Erases ALL !!!
Reject command
EXECUTE CMD
Performs an in-depth test of the system. Test takes
several minutes to complete and erases all setup data.
View menu, special
measurement, alarm &
command codes
NEXT
Allows you to scroll through a list of the codes for
commands, special measurements (add offset of 1024
to measurement number), and alarms.
Do not use break tab
distance correction
Change to “Do”
Continue as is.
Hardware Diagnostics (Factory Service Submenu)
Display Comments
hardware status:
DSP BRD
Indicates DSP board is installed.
hardware status:
relays installed
Indicates relays are installed.
Soc 1 board type:
current-relay
Board type installed in transmitter PCB slot #1.
Soc 2 board type:
none
Board type installed in transmitter PCB slot #2.
Soc 3 board type:
DSP
Board type installed in transmitter PCB slot #3.
Soc 4 board type:
none
Board type installed in transmitter PCB slot #4.
current outputs = 1
Number of current outputs installed.
relays = 2
Number of relays installed.
Switch INPUTs = 2
Number of contact closure inputs installed.