Instruction Manual
Installation and Operation Handbook Ordering Code
2416 Controller A-3
Part 1B: Hardware coding
Plug-in modules
Module
2
Module
3
Comms
1
Manual
RC RH MB ENG
Continue next page ►
Module 2
XX None
Relay: 2-pin
R2 Fitted unconfigured
RC PID cooling
RW Valve lower output
PO Program event output 1
Or Alarm 2: select from table A
Logic non- isolated
L2 Fitted unconfigured
LC PID cooling
Triac
T2 Fitted unconfigured
TC PID cooling
TW Valve lower output
DC control non-isolated
D2 Unconfigured
C1 0-20mA cooling
C2 4-20mA cooling
C3 0-5Vdc cooling
C4 1-5Vdc cooling
C5 0-10Vdc cooling
Comms
XX None
EIA-485 ( 2 wire )
Y2 Fitted unconfigured
YM Modbus protocol
YE EI Bisynch protocol
EIA-232
A2 Fitted unconfigured
AM Modbus protocol
AE EI Bisynch protocol
EIA-485 ( 4 wire )
F2 Fitted unconfigured
FM Modbus protocol
FE EI Bisynch protocol
PDSIO input
M6 Fitted unconfigured
RS Setpoint input
PDSIO output
M7 Fitted unconfigured
PT PV retransmission
TS Setpoint retrans
OT Output retrans
Module 3
XX None
Relay: 2-pin
R2 Fitted unconfigured
PO Program event 2
LF PDSIO load failure
HF PDSIO heater failure
SF PDSIO SSR failure
Or Alarm 4 select from table A
Other modules
L2 Logic unconfigured
non-isolated
T2 Triac unconfigured
D2 DC unconfigured
non- Isolated
First character
V−
PV retransmission
S−
Setpoint retransmission
O−
Output retransmission
Z−
Error retransmission
Second character
−1
0 to 20mA
−2
4 to 20mA
−3
0 to 5V
−4
1 to 5V
−5
0 to 10V
Manual
XXX No manual
ENG English
FRA French
GER German
ITA Italian
►Continued