Instruction Manual

Configuration Installation and Operation Handbook
6-2 2416 Controller
6.1 SELECTING CONFIGURATION LEVEL
There are two alternative methods of selecting Configuration level:
If you have already powered up, then follow the access instructions given in Chapter 3,
Access levels.
Alternatively, press
and together when powering up the controller. This will
take you directly to the ConF password display.
6.1.1 Password entry
When the ConF display appears, you must enter the
Configuration password (which is a number) in order to
gain access to Configuration level.
Enter the password using the
or buttons.
The configuration password is set to 2 when the
controller is shipped from the factory.
Once the correct password has been entered, there is a two
second delay, after which the lower readout will change to
PASS indicating that access is now unlocked.
Note: A special case exists if the password has been set to
0. In this situation, access is permanently unlocked and
the lower readout will always show PASS’.
Press to enter configuration.
(If an incorrect password has been entered and the
controller is still ‘locked’ then pressing
at this point
will take you to the Exit display with no in the lower
readout. Simply press to return to the ConF
display.)
You will obtain the first display of configuration.
Conf
Conf
Conf
pass
inst
Conf