Instruction Manual

Programmer Operation Installation and Operation Handbook
5-14 2416 Controller
Event output 1 (not 8-segment programmer)
Appears in all segments, exceptcALL’ segments.
Use
or to set output 1:
OFF Off in the current segment
on On the current segment.
Press
Further event outputs
(not 8-segment programmer)
Up to eight (8) event outputs may appear in this list where ‘n’ =
event number .
Pressing
will step through all the remaining event outputs. In
practice, the 2416 has a maximum of three physical outputs,
although more than one event can be combined onto a single
physical output. See Chapter 6, Configuration.
Use
or to set:
OFF Off in the current segment
on On the current segment.
Press
End segment type
Use
or to select:
dwEl An indefinite dwell
rSEt Reset
S OP End Segment Output Power Level
Press
Power Value [End Segment]
Use
or to set the power value in the range ±100.0%.
This power level is clipped by the parameters ‘OP.Hi and
OP.Lo before being applied to the process.
Note: In programmer/controller software versions 3.56
onwards, this parameter has been replaced by a parameter
End.P which appears at the end of the output list, see Chapter
2.
Press
to return to the ProG-LiSt header.
End.t
dwel
pwr
0.0
out1
Off
outn
on