5-12 2416 Controller
Segment type
Select the segment type using
or :
rmP.r Ramp to a new setpoint at a set rate
rmP.t Ramp to a new setpoint in a set time
dwEl Dwell for a set time
StEP Step to a new setpoint
cALL Call another program as a subroutine
(only available in 4-program controllers)
End Make this segment end of program.
Press
The parameters that follow tYPE depend on the type of segment selected.
Parameter Segment type selected
rmP.r rmP.t dwEl StEP cALL End
Hb
9 9 9 9
tGt
9 9
9
rAtE
9
dur
9 9
PrG.n
9
outn
9 9 9 9
9
cYc.n
9
dwEl
9
End.t
9
Pwr
9
Table 5-3 Parameters that follow segment tYPE
Holdback type
[Only appears when Holdback per segment has been selected.]
Use or to select:
OFF: Holdback disabled
Lo: Deviation Low Holdback
Hi: Deviation High Holdback
bAnd: Deviation Band Holdback
Press
Target setpoint
Target setpoint for rmP.r, rmP.t or StEP segments.
Set the target setpoint using
or .
Press
Continued on the next page.
Hb
bAnd
tgt
100
type
rmp.r