Instruction Manual

Installation and Operation Handbook Understanding The Ordering Code
2408 and 2404 Controller A-3
Part 1B: Hardware coding
Plug-in modules Plug-in modules
continued Module
2
Module
3
Alarm
relay
Comms
1
Comms
2
Manual
RC FL FH YM TS ENG
* fitted unconfigured
Module 2
XX Not fitted
Relay: 2-pin
R2 Fitted unconfigured
RC Cooling output
RW Valve lower output
Relay: change-over
R4 Fitted unconfigured
YC Cooling Output
RL Valve lower (note 6)
PO Program event output 1
(note 7)
PE Program END segment
Or Alarm 2: select from table A
Dual relay
RR Fitted unconfigured
PP Program events 1 & 2
(note 7)
Logic (non-isolated)
L2 Fitted unconfigured
LC PID cooling
Logic (isolated)
LO Single logic output *
Triac
T2 Fitted unconfigured
TC PID cooling
TW Valve lower output
DC control isolated
D4 Fitted unconfigured
C6 0-20mA PID cooling
C7 4-20mA PID cooling
C8 0-5V PID cooling
C9 1-5V PID cooling
CZ 0-10V PID cooling
Digital I/O (unconfigured)
TK Triple contact input
TL Triple logic input
TP Triple logic output
Power supply
MS 24Vdc transmitter
DC retran (isolated)
Selct from table B
Potentiometer input
VU Fitted unconfigured
VS Valve position feedback
VR Setpoint input
Transducer PSU
G3 5Vdc
G5 10Vdc
Comms 1
XX None
2-wire EIA-485
Y2 Fitted unconfigured
YM Modbus protocol
YE EI Bisynch protocol
(note 1)
RS-232
A2 Fitted unconfigured
AM Modbus protocol
AE EI Bisynch protocol
(note 1)
4-wire RS-485
F2 Fitted unconfigured
FM Modbus protocol
FE EI Bisynch protocol
(note 1)
PDS output
M7 Fitted unconfigured
PT PV retransmission
TS Setpoint retrans
OT Output retrans
Profibus module
PB High speed RS485
DeviceNet
DN DeviceNet
Comms 2
XX Not fitted
PDS input
M6 Fitted unconfigured
RS Setpoint input
PDS output
M7 Fitted unconfigured
PT PV retransmission
TS Setpoint retrans
OT Output retrans
Module 3
XX Not fitted
Relay: 2-pin
R2 Fitted unconfigured
Relay: change-over
R4 Fitted unconfigured
PO Program event 4 (note
7)
PE Program END output
Or Alarm 3 select from table A
Logic (non-isolated)
L2 Fitted unconfigured
Logic (isolated)
LO Single logic output *
Triac
T2 Fitted unconfigured
Dual relay
RR Fitted unconfigured
PP Program event 4 & 5
(note 7)
Digital I/O (unconfigured)
TK Triple contact input
TL Triple logic input
TP Triple logic output
Power supply
MS 24V transmitter
DC remote input
D5 Fitted unconfigured
W2 4 to 20mA setpoint
W5 0 to 10V setpoint
WP Second PV input
DC retran (isolated)
Select from table B
Potentiometer input
VU Fitted unconfigured
VS VP feedback
VR Setpoint input
Transducer PSU
G3 5Vdc
G5 10Vdc
Manual
XXX No manual
ENG English
FRA French
GER German
NED Dutch
SPA Spanish
SWE Swedish
ITA Italian
Alarm relay
XX Not fitted
Alarm 4 relay
RF Fitted unconfigured
Table A alarm options plus:
RA Rate of change
PDS alarms
LF Heater break detect
HF Current monitor heater brk
SF Current monitor SSR fail
PO Program event 7 (note 7)
PE Program END output