Installation Guide
Doc No. 81159 Page 9 of 17 Rev D 1/17 JWJ
In Room Tempature Sensing device
NOTE: DO NOT mount sensor near the steam head!
1. Install the Temperature Control sensor with bulb guard in the steam room 4 to 6
feet above the floor. Drill two ¼” holes (Screw Inserts) and one 3/8” hole (sensor
wire)
2. Bring the control sensor wire to the master controller through conduit. Connect
the control sensor wires, using ¼” push-on connectors, to the control panel
connector labeled “TEMP SENSOR”.
3. Silicone all trough holes with supplied silicone to ensure all holes don’t allow
moisture to get from steamroom into the wall.
4. Connect the Control Timer to the “TIMER” connection on the control panel using
the two (supplied) wire nuts connectors.
5. Install the temperature control sensor with bulb guard in the steam room 4 to 6
feet above the floor.
Failure to follow installation instructions specifically may cause the warranty to be void!
1 ¼”
6 ¼”
Silicone as required 3 places