Installation Guide
Doc No. 81159 Page 13 of 17 Rev D 1/17 JWJ
5. Pressing the SET button will let you see the “Standby” steam
room temperature, and enable you to configure it. Upon a first
press of UP or DOWN, the Function LED will start blinking and
the standby temperature will be displayed. Using the arrows, set
the temperature you want to be stored as the “Standby
Temperature”. In auto mode the Generator will use this
temperature for maintaining and keeping the steam room at the
constant desired temperature when the steam room is not
occupied or the mechanical timer is off. This temperature is
applied to all 7 days of the week. If the unit is in “Override”
mode, this setting is ignored.
6. Pressing the SET button once again will enable you to set the
“Power Flush System” availability time. You should see the light
next to the “Power Flush Time” come on and the display will show
the Power Flush time for the configuration day. Using the arrows,
set the time you want the flush to be available for that day from
now onward, press the DAY button for each day and using the
arrows to set the time you want the unit to begin its Power Flush
cycle. Once again the use of ALL for the day will apply the setting
to all 7 days while pressing the DAY button will allow you to
modify the time for any specific day. The Power Flush stops
automatically at the end of its cycle (Approximately 45 minutes).
Power Flush start time can occur before start time (00:00
midnight, with 07:00 start) or after hours (20:00 stop time, and
23:00 Power Flush start).
7. Pressing the SET button once again will display the days
remaining until the next actual Power Flush cycle is to
commence. It will also display the day of the week this event is
scheduled to occur. This figure is a function on the Set interval
requested and the actual usage of the steam room. In order to
change the desired interval, while in this mode, press and hold
the SET button for 5 seconds. The SET LED will start blinking;
Press the UP or DOWN buttons to adjust the required interval.
This interval is a function of water hardness and condition. It will
be adjusted for optimum conditions by qualified user or by the
ThermaSol CSR.