Installation Guide

Doc No. 81159 Page 12 of 17 Rev D 1/17 JWJ
ThermaSol SUPERDUTY
Control Operating Instructions
BEFORE PROCEEDING MAKE SURE ALL WATER SUPPLY, STEAM AND PRV
CONNECTIONS ARE COMPLETE AND WATER IS TURNED ON. INSPECT FOR LEAKS AND
ALLOW TANK TO COMPLETELY FILL. MAKE SURE NO ELECTRICAL SHORTS OR EXPOSED
WIRES ARE PRESENT, GENERATOR IS PLUGGED IN AND BREAKER IS ON.
1. Ensure electrical/plumbing installation is complete (see page 8)
turn on power to unit at the breaker/disconnect box. The display will
reset to 00:00 and then display the current time of day. If the time
and/or day of week are not correct, press DAY or UP/DOWN
buttons once to get to set clock menu, the CLOCK SET LED will
start blinking. Press the day to adjust the correct day of the week.
Press UP or DOWN to adjust the time. After 5 seconds, the system
will accept this as the valid time. You can also press SET button to
accept. The time displayed is a 24-hour clock while the day of the
week is marked by an LED next to the DAY label.
2. Now you will set the “Steam Start Time”. Press the SET button
once. You should see the light next to the “Start Time” come on and
a red light next to ALL day. The ALL feature sets the start time for
all 7 days. This saves time on entering redundant information 7
times. Using the DAY button, you can customize the availability of
steam and individually change the start time on specific days. Press
UP or DOWN once to enter the Start Time” change menu – The
LED will start blinking. The system comes from the factory with
default values of 7:00 start time for all seven days. Using the
arrows, set the time you want the steam to be available on that day
from now onward.
3. Next, set the “Steam Stop Time” using a similar method as the Start
Time. Press the SET button once. You should see the light next to
the “Stop Time”. Press UP or DOWN once to enter the “Stop Time”
change menu The LED will start blinking. Using the arrows, set
the time you want the steam to stop for that day from now onward.
Note that you are either programming a specific day or ALL (1 full
week). If ALL was the day configured, the settings will be applied to
all 7 days. If there is a need to modify specific days, press DAY to
move to the desired day to modify the time settings.
4. Pressing the SET button will let you see the current steam room
temperature, and also enable you to configure the Temperature Set
Point. Upon a first press of UP or DOWN, the Function LED will
start blinking and the set point will be displayed. Using the arrows,
set the temperature you want to be stored as the Set Point. This
Generator will use this temperature as a threshold for maintaining
and keeping the steam room at the constant desired temperature.
This temperature is applied to all 7 days of the week.
.
.
.
.
.
.
.
.
.
.
.
.