Doc No. 81159 Page 10 of 17 Rev D 1/17 JWJ
OUTSIDE ROOM 30 Minute Timer device
Do Not Mount inside the steamroom
1. Outside of the steam room door, install the 30 minute timer device. This allows
the generator, when room is not occupied, to reduce the room tempature and
save energy.
Note: After installation you can override timer with main control panel see pg. 14
2. Bring the Timer Device wire to the master controller through conduit. Connect the
control sensor wires, using ¼” push-on connectors, to the control panel labeled
“TIMER”.
3. Using a single gang box, attach the 30 Minute Timer lead connections with the
supplied wire to the timer. Using the suplied screws with the timer box, screw the
timer onto the single gang box.
4. Drill one ¼” hole from center of timer box down: 11-1/8 for screw anchor.
5. Screw back plate to box and the lower anchor. (3 places)
6. Place the Timer knob onto the Timer shaft using the supplied set screw and
5/32
nd
hex wrench. Tighten firmly against the flat surface of the Timer shaft.
Failure to follow installation instructions specifically may cause the warranty to be void!
MASTER CONTROLLER
11-1/8”