Installation Guide

Doc No. 81159 Page 2 of 17 Rev D 1/17 JWJ
Sizing Your Steam Room
Steam Room Size Formula: L X W X H = volume in cubic feet (ft
3
)
All measurements are to be in units of feet. For non-standard ceilings (above 8 ft. high), apply a
correction factor (add 10% per foot).
Examples: For a 9 ft. ceiling, the formula requires correction factor of 1.1 x (room size)
For a 10 ft ceiling, the formula requires correction factor of 1.2 x (room size)
For further assistance call toll-free: 800-776-0711
Model
Description
Total Room Volume: CF
TSD-600-240
SuperDuty Generator 15 kW, 240V
Up to 600 Cubic Feet
TSD-900-240
SuperDuty Generator 18 kW, 240V
Up to 900 Cubic Feet
TSD-1200-240
SuperDuty Generator 24 kW, 240V
Up to 1200 Cubic Feet
TSD-1600-240
SuperDuty Generator 30 kW, 240V
Up to 1600 Cubic Feet
TSD-600-480
SuperDuty Generator 15 kW, 480V
Up to 600 Cubic Feet
TSD-900-480
SuperDuty Generator 18 kW, 480V
Up to 900 Cubic Feet
TSD-1200-480
SuperDuty Generator 24 kW, 480V
Up to 1200 Cubic Feet
TSD-1600-480
SuperDuty Generator 30 kW, 480V
Up to 1600 Cubic Feet