Specification Sheet


92002‐575_NC
SSA-575
Steamshower AF - Steam Generator
Rou
g
h-In Guide
SPECIFICATIONS
Input Voltage……………...….208-240VAC Single Phase
Kilowatt Rating……………………………………..……15.0
Maximum Amperage…………………………..….69 AMPS
Water Inlet………………………………..…………3/8” NPT
Steam Outlet………………………………….…….1/2” NPT
Safety Valve……………………………………..….3/4” NPT
Electrical Connection………………...………..Hardwired
Maximum Room Size (cubic Feet)…………………....575
• Can be plumbed 50 ft. from the shower
• Superior heating elements - low watt density
• Stainless steel construction
• 208-240 volt plug-in power cord (5 ft.)
• Water tight data link cable for control
InstallationNotes:
Installthisgeneratoraccordingtothesuppliedinstallationguide.Follow
localplumbingandelectricalcodes.Unitmustbeaccessible.
Generatorisfactorysized:LxWxH=CubicFeet.Choosetheappropriate
generator.Foreveryadditionalfootofceilingheightover8ft,usethenext
largergenerator.Alwaysroundupwhencalculatingthetotalcubicfeet.
Compatibleoptions:
‐ThermatouchSeries
‐SignatouchSeries
‐MicrotouchSeries
‐SignatureControlSeries
‐EasyStartSeries
‐WellnessPackages
‐DigitalShowerPackages
‐SerenityLightandMusicseries
ShippingInformation:
Weight…………..45lbs.
Length…………..…22in.
Width…………..….18in.
Height……………..14in.
65259205526
ProductUPCCode
ForanyfurtherassistancepleasecontactThermaSolat
800.776.0711orsales@thermasol.com
Visitwww.thermasol.comforacompleteproductdefinition
ProductSpecification:
Thesteamgeneratorshallbeapproximately18”x13.75”x12”indimension.Thegeneratorshallbemadefrom
stainlesssteelandinclude:FastStart,AutoPowerFlush,SplitTank,andusea100%networkeddigitaltechnology.
Steamshower AF – Standard Equipment:
• Auto PowerFlush – pressurized inner tank cleaning system
• Lifetime factory Warranty
• 2 year in-home warranty prior to the lifetime warranty
FastStart – steam in seconds… not minutes (patented)
• Constant steam at a constant rate
• Split tank enhances performance and life-span

Summary of content (1 pages)