Installation Sheet
4
THERMASOL.COM
I
800.776.0711
Select a location as near as practical to the steam shower.
Typical locations include: closet, vanity cabinet, climate
controlled attic or basement.
Be sure to install unit in a location that offers easy
accessibility for servicing of generator. (Power Flush
maintenance is recommended every 1000 minutes
of use.)
DO NOT install generator inside steam room.
DO NOT install generator or plumbing lines in unheated
attic or any locations where water could freeze.
DO NOT install generator outdoors or wherever
environmental conditions may affect the safety
and/or performance of the generator.
Generator may be installed up to 50 feet away from steam
shower and must be in a dry, non-combustible, well
ventilated space with 6" clearance around generator.
When constructing the ceiling add slope of 1"/foot. The
control cable provided with the generator is 50 feet in
length (Item 03-6152-050).
When locating the control unit, place it as far as possible
away from the steam head and as close as is practical to
where the user will be sitting.
The generator must be upright, accessible and on a
level surface with all connections on top. Access panel
must be unobstructed and allow for easy access.
Example of different
generator locations.
Read warnings on page 2. For illustrative purposes only. Consult with qualied professional for steam room construction details.
5 Placing the Generator
PRO Series Generator Installation Instructions