Installation Sheet
9
THERMASOL.COM
I
800.776.0711
Power Pak Series 3 Generator Installation Instructions
8 In Room Temperature Sensing Device Installation
NOTE
DO NOT mount the sensor near the steam head!
1. Install the temperature control sensor with a bulb guard in the steam room 4 to 6 ft. above the oor. Drill two 1/4" holes
for screw anchors and one 3/8" hole for the sensor wire located as shown below.
2. Bring the sensor wire to the temperature control sensor through the conduit and pass it through the 3/8” hole. Connect
the control sensor wires using the bullet connections provided on the temperature control sensor and sensor wire.
3. Carefully feed any excess wire into the wall and silicone all holes with supplied silicone to ensure holes do not allow
moisture to get from steam room into the wall.
4. Attach the temperature control sensor to the wall with the supplied fasteners. Take care not to over torque fasteners
and damage screw anchors.
5. Do not staple temp sensor wires.
6. Locations near the steam room entrance/exit door are optimal.
Failure to follow installation instructions may cause the warranty to be void.
Read the warnings on page 2. For illustrative purposes only. Consult with a qualied professional for steam room construction details.
6¼"
Silicone as required in 3 places
Center hole 3"
from right side