Installation Sheet

6
THERMASOL.COM
I
800.776.0711
Power Pak Series 3 Generator Installation Instructions
6 Electrical Installation
Model Description Volts KW Amps Wire Breaker Phase Room Volume
PP18SR-240
PowerPak Series 3 Generator
18 kW, 240V
208/240 18kW 44 6 60 3 < 1000 Cubic Feet
PP24LR-240
PowerPak Series 3 Generator
24 kW, 240V
208/240 24kW 58 6 70 3 ≥ 1000 Cubic Feet
PP18SR-480
PowerPak Series 3 Generator
18 kW, 480V
480 18kW 22 6 30 3 < 1000 Cubic Feet
PP24LR-480
PowerPak Series 3 Generator
24 kW, 480V
480 24kW 29 6 40 3 ≥ 1000 Cubic Feet
NOTE
All electrical wiring must be done per local electrical codes and by a
licensed electrical professional.
Wire sizes are recommended by National Electric Code. The minimum wire temperature rating is 90 °C.
Turn off all electricity to the working area at the main breaker panel prior to installation.
1. Have a licensed electrical professional connect the 240 or 480 VAC.
The system uses 4 conductor wires (3 phase and a ground).
Read the warnings on page 2. For illustrative purposes only. Consult with a qualied professional for steam room construction details.