Installation Sheet

Power Pak Series 3 Generator Installation Instructions
5
THERMASOL.COM
I
800.776.0711
1. Install a 3/8" ball valve to a COLD water line. Place the water pipe outlet within 6" of the labeled water inlet
2. Before making the last connection to the 3/8" water inlet line coming into the unit, ush the water line into a
ve-gallon pail to remove any silt or other material that may be in the line. IMPORTANT - Not doing so may effect the
water delivery to the unit.
3. Make the nal connection, then turn on the water. All ThermaSol generators are equipped with an automatic water
ll system. The water will stop after unit is lled.
4. Thoroughly check for any leaks.
5. Max water pressure is 70 psi. Minimum water pressure is 40 psi.
5 Water Inlet Installation
Read the warnings on page 2. For illustrative purposes only. Consult with a qualied professional for steam room construction details.
NOTE
All plumbing must be done per local plumbing codes and by a
licensed plumbing professional.