Installation Sheet
Power Pak Series 3 Generator Installation Instructions
5
THERMASOL.COM
I
800.776.0711
1. Install a 3/8" ball valve to a COLD water line. Place the water pipe outlet within 6" of the labeled water inlet
2. Before making the last connection to the 3/8" water inlet line coming into the unit, ush the water line into a
ve-gallon pail to remove any silt or other material that may be in the line. IMPORTANT - Not doing so may effect the
water delivery to the unit.
3. Make the nal connection, then turn on the water. All ThermaSol generators are equipped with an automatic water
ll system. The water will stop after unit is lled.
4. Thoroughly check for any leaks.
5. Max water pressure is 70 psi. Minimum water pressure is 40 psi.
5 Water Inlet Installation
Read the warnings on page 2. For illustrative purposes only. Consult with a qualied professional for steam room construction details.
NOTE
All plumbing must be done per local plumbing codes and by a
licensed plumbing professional.