ThermaSol Power Pak Series 3 Control Operating Instructions
Controller Notes and Tips
• The system will revert to displaying the current time and day after 1 minute of no button activity. The SET
button is used to select between various display settings.
• The ALL feature is extremely useful, as it enables the ability to quickly set START, STOP, and SYSTEM POWER
FLUSH times for all 7 days. Then, on days such as weekend days, the user can modify only those days–
eliminating the need to enter redundant information.
• The START, STOP, and SYSTEM POWER FLUSH times are related to each other automatically. The system is
shipped from the factory with default values of 7:00 START, 20:00 STOP, and 23:00 POWER FLUSH for all 7
days. The user can always revert (reset) back to these original factory defaults by pressing and holding the UP
and DOWN buttons simultaneously from the diagnostics menu for 5 seconds.
• If the START TIME reaches the STOP TIME, the system will automatically x that by pushing the STOP
TIME forward. Similarly, if the STOP TIME reached the START TIME, it will attempt to push the START TIME
backwards (if possible) until reaching 00:00. If both times reach within 5 minutes of the Power Flush time,
the system will try to jump to 50 minutes past the SYSTEM POWER FLUSH time, if it is unsuccessful, it will
maintain the previous settings.
• The system supports temperature in both Fahrenheit and Celsius with a default factory setting of Fahrenheit.
To change the units to Celsius, press the SET button until you reach the temperature menus. Press and hold
the SET button for 5 seconds and release and the temperature format will change.
• The AUTO/OVERRIDE mode button overrides the STANDBY TEMPERATURE such that the room will be
maintained at the temperature set point as long as the remote timer timer is ON. The Steam generator will
be completely off when the remote timer is in the OFF position. To switch to override mode, simply press the
AUTO/OVERRIDE button and the OVERRIDE LED will light up. To switch back to AUTO/STANDBY mode,
simply press the AUTO/OVERRIDE button again, the AUTO LED will light.
• The system is equipped with special diagnostics features that are accessible using the diagnostics menu.
From the START or STOP menus, press and hold the SET button for 5 seconds. The display will then show
and cycle between the following screens.
• The system is equipped with an error messaging system. Upon a system malfunction, an error message will
be displayed with the following code numbers:
F xx Firmware of Control
P xx Firmware of Power Pak Generator
U xxx Supply Voltage
xyza Total Lifetime Hours of Steam Generation (increments of 10 hours)
xyza Total Number of Power Flush Cycles Completed
xyza Total Number of Power Flush Cycles Attempted
E80 Tank Overpressure Error
E90 Over Temperature Error
E91 Low Water Error
E95 Low AC Voltage Error
E96 High AC Voltage Error
E97 Tank Temp is too high or bad (shorted) sensor
E98 Temp Sensor low/disconnected Error
E99 Communication Error
E100 Lost Communication with Generator
E120 Room Temp Sensor is shorted
E121 Room Temp Sensor is open / disconnected
E122 Temp Control Error
E190 Stuck Button Error (Down)
E191 Stuck Button Error (Manual)
E192 Stuck Button Error (Up)
E193 Stuck Button Error (Function)
E194 Stuck Button Error (Pause)
E195 Stuck Button Error (Day)
E196 Gen Error